Nilfisk-ALTO POSEIDON 3 Service Manual page 33

Hide thumbs Also See for POSEIDON 3:
Table of Contents

Advertisement

Valve Maintenance 3~
Fig.F.17: Valve Block 3 ~ - Plug removal
To take out the valves remove the six screw
plugs (17 mm wrench).
Pull out the valves by means of a nose pliers.
Bear in mind the o-ring.
Inspect valves/seats and replace if necessary.
Grease o-ring lightly.
Fig.F.19: Valve Kit 3~ - Exploded View
Numbers refer to spare parts catalogue.
5 - O-ring
27 - Valve kit
28 - O-ring
29 - Spacer
30 - Plug
sm_POSEIDON 3_en_Ver.1.0_11.07
Service / Repair
Fig.F.18: Valve Block 3 ~ - Valve replacement
Place the valve assembly in the valve chamber.
Press down firmly on top of the valve with your
finger.
Fit screw plug applying Loctite 243.
Torque 44 Nm (33 ft.lbs.)
Fig.F.20: Pressure valve 3 ~ - Cut Away View
As shown on the cut-away view the spacer
(29) is not used for the center valve.