Valve Maintenance
Fig.F.9: Valve Block 1~
To carry out valve maintenance on the 1~
•
machine, it is necessary to dismount
valve block from pump housing.
Fig.F.11: Valve Block 1~ Removel
To dismount valve block:
Remove end switch.
•
Unscrew HP-hose.
•
Remove detergent hose.
•
Loosen and remove the four hexagon bolts.
•
sm_POSEIDON 3_en_Ver.1.0_11.07
Service / Repair
Fig.F.10: Valve Block 3~
On the 3~ machine the valve block can
•
remain in place.
Fig.F.12: Valve Block 1~ Removel
Use a plastic hammer to carefully tap the
•
valve block loose.
At assembly, torque setting for the four
•
hexagon screws M8x55 is 24 Nm (18 ft.lbs.).
Note ! Three phase screws M8x50.
•
F
31