[SENSING]-[CALC]-[CALC]-[STEP]
3.
Set the expression of TASK1.
INPUT X: INPUT A
INPUT Y: INPUT B
4.
Following the same procedure as 2 to 3, set
up TASK2.
INPUT X: INPUT A
INPUT Y: INPUT C
• To output the judgment result of the operation
[I/O SET]-[I/O SET]-[OUT]
5.
Select TASK1 or TASK2 depending on the
details to be output.
To output judgment on the difference between point A (reference point) and point
B: Set TASK1 to I/O SET
To output judgment on the difference between point A (reference point) and point
C: Set TASK2 to I/O SET
• To linear-output the operation result
[I/OSET]-[I/O SET]-[ANALOG]
5.
Select TASK1 or TASK2 depending on the
details to be output.
To output the difference between point A (reference point) and point B: Set TASK1
to I/O SET
To output the difference between point A (reference point) and point C: Set TASK2
to I/O SET
The calculation results of each CH can be batch-acquired if you use the communication command.
Measuring the Reference Difference between Steps
Section 4
1
INPUT X
2
INPUT Y
Input A
Input B
Y X
Input A
Input B
Input C
X
1
TASK1
2
TASK2
3
TASK3
4
TASK4
1
TASK1
2
TASK2
3
TASK3
4
TASK4
ZS-MDC
User's Manual
Input C
Y
4-9