Important: Always keep the battery fully charged
(1.265 specific gravity). This is especially important
to prevent battery damage when the temperature is
below 32°F (0°C).
1. Make sure the filler caps are installed in battery.
Charge battery for 10 to 15 minutes at 25 to 30 amps
or 30 minutes at 10 amps.
2. When the battery is fully charged, unplug the charger
from the electrical outlet, then disconnect the
charger leads from the battery posts (Figure 49).
3. Install the battery in the machine and connect the
battery cables, refer to Installing the Battery.
Note: Do not run the machine with the battery
disconnected, electrical damage may occur.
1. Positive Battery Post
2. Negative Battery Post

Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance, however, if a fuse blows check
component/circuit for malfunction or short.
1. Unlatch the engine hood and raise the engine hood
to gain access to fuse holder (Figure 50).
2. To replace the fuses, pull out on the fuse to remove
it.
3. Install a new fuse (Figure 50).
Figure 49
3. Red (+) Charger Lead
4. Black (-) Charger Lead
1. Ignition-30 amp (F1)
2. Radiator fan-40amp (F2)
40
Figure 50
3. Clutch-10 amp (F3)
4. Left side fuel tank