Hydraulic System Maintenance; Servicing The Hydraulic System - Toro Z580-D Z Master 74266 Operator's Manual

With a 52in, 60in or 72in turbo force side discharge mower
Hide thumbs Also See for Z580-D Z Master 74266:
Table of Contents

Advertisement

9. Apply slight rearward pressure on the motion
control lever, turn the head of the adjustment bolt
in the appropriate direction until the control lever is
centered in the neutral lock position (Figure 73).
Note: Keeping rearward pressure on the lever will
keep the pin at the end of the slot and allow the
adjustment bolt to move the lever to the appropriate
position.
10. Tighten the nut and jam nut (Figure 73).
11. Repeat for the opposite side of the machine.
Figure 73
1. Height-of-cut lever
2. Nut against yoke
3. Jam Nut
4. Clevis pin in slot
5. Adjustment bolt
6. Yoke
7. Spring
Hydraulic System
Maintenance
Servicing the Hydraulic
System
Checking the Hydraulic Fluid
Service Interval: After the first 8 hours
Every 25 hours
Fluid Type: Mobil 1 15W-50 synthetic motor oil or
equivalent synthetic oil.
Hydraulic System Oil Capacity: 132 ounces (3.9 l)
Important: Use oil specified or equivalent. Other
fluids could cause system damage.
Note: There are two ways of checking the hydraulic oil.
One is when the oil is warm and one is when the oil is
cold. The baffle inside the tank has two levels depending
if the oil is warm or cold.
1. Position the machine on a level surface and set the
parking brake.
2. Clean the area around filler neck of hydraulic tank
(Figure 74).
3. Remove the cap from the filler neck. Look inside to
check if there is fluid in the reservoir (Figure 74).
4. If there is no fluid, add fluid to the reservoir until it
reaches the cold level of the baffle.
5. Run the machine at low idle for 15 minutes to allow
any air to purge out of the system and warm the fluid.
Refer to Starting and Stopping the Engine in , page .
6. Recheck the fluid level while the fluid is warm. The
fluid should be between cold and hot.
7. If required, add fluid to the hydraulic tank.
Note: The fluid level should be to the top of the hot
level of the baffle, when the fluid is hot (Figure 74).
8. Install cap on filler neck.
51