Canon VB-C60 Start Manual page 74

Hide thumbs Also See for VB-C60:
Table of Contents

Advertisement

Input/Output Terminals
External Device Output Terminals (OUT1, OUT2)
There are two sets of external device output terminals (OUT1, OUT2), where each set consists of
two terminals. Each terminal set has no polarity. The condition between the two terminals can be
switched between connected and disconnected by controlling from the viewer. The output
terminals are isolated from the internal circuits of the camera using optical couplers.
The loads connected to the output terminals should be used within the following ratings:
Ratings between output terminals: Maximum voltage 50 VDC
Internal Connection Diagram
Tip
Applicable wire for external device cable
Single AWG No.28 to 22
Conductor size Φ0.32 to 0.65 (mm) (0.013 to 0.026 in)
Strip the cable by approx. 8 to 9 mm (0.315 to 0.354 in).
3-6
Continuous load current 100 mA max.
Ω
Ω
10k
10k
External
device
µ
0.1
F
+3.3V
Ω
10k
Input terminal
IN1, IN2
External
Output terminal
device
OUT1, OUT2