Installer Settings: Tables To Be Filled In By Installer; Quick Wizard; Space Heating Control; Domestic Hot Water Control [A.4] - Daikin Altherma EGSQH10S18AA9W Operation Manual

Ground source heat pump
Hide thumbs Also See for Altherma EGSQH10S18AA9W:
Table of Contents

Advertisement

4 Energy saving tips

INFORMATION
Depending on the selected installer settings, settings will
be visible/invisible.
3.8
Installer settings: Tables to be
filled in by installer
3.8.1

Quick wizard

Setting
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate
Space heating settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
Domestic hot water settings [A.2.2]
DHW pump
Thermostats [A.2.2]
Contact type main
Contact type add.
External sensor
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
Alarm output
Demand PCB [A.2.2.7]
Demand PCB
Energy metering [A.2.2]
External kWh meter 1
External kWh meter 2
Capacities (energy metering) [A.2.3]
BUH: step 1
BUH: step 2
Auto emergency [A.5.1.2]
Emergency
INFORMATION
Auto emergency: By default, backup heater operation
during emergency operation is NOT allowed. This means
that when a heat pump failure occurs the user needs to
manually confirm that backup heater may operate during
emergency. If the house is unattended for longer periods,
we recommend that setting [A.5.1.2] Emergency shall be
set to Automatic.
3.8.2

Space heating control

Setting
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
Leaving water temperature: Delta T source [A.3.1.3]
Heating
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
Operation manual
8
Default
Fill in...
0 (No)
0 (LWT control)
1 (In room)
0 (1 LWT zone)
1 (Sample)
0 (No)
1 (Thermo ON/
OFF)
1 (Thermo ON/
OFF)
0 (No)
0 (No)
0 (Normally open)
0 (No)
0 (No)
0 (No)
3 kW
3 kW
Manual
Default
Fill in...
1 (Weather dep.)
1 (Weather dep.)
8°C
0 (No)
Setting
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
3.8.3

Domestic hot water control [A.4]

Setting
Type
Maximum setpoint
3.8.4

Contact/helpdesk number [6.3.2]

Setting
Contact/helpdesk number
4
Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.
▪ Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
▪ When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
▪ Use a weekly schedule for your normal space heating needs. If
necessary, you can easily deviate from the schedule:
▪ For shorter periods: You can overrule the scheduled room
temperature. Example: When you have a party, or when you
are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode. Example:
When you stay at home during your holiday, or when you go
away during your holiday.
Tips about DHW tank temperature
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode).
▪ Program to heat up the DHW  tank to a preset value (Storage
comfort = higher DHW  tank temperature) during the night,
because then space heating demand is lower.
▪ If heating up the DHW  tank once at night is not sufficient,
program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.
▪ Make sure the desired DHW  tank temperature is NOT too high.
Example: After installation, lower the DHW tank temperature daily
by 1°C and check if you still have enough hot water.
▪ Program to turn ON the domestic hot water pump only during
periods of the day when instant hot water is necessary. Example:
In the morning and evening.
5

Maintenance and service

5.1
Overview: Maintenance and
service
The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.
As end user, you have to:
Default
Fill in...
0 (Quick)
Default
Fill in...
1 (Reheat +
sched.)
60°C
Default
Fill in...
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351750-1D – 2015.10

Advertisement

Table of Contents
loading

Table of Contents