electrical supply by a suitably registered person.
cause a safety hazard.
upply circuits must be disconnected. Failure to do so may result
Single phase connection:
cuit is protected by a suitably rated Miniature Circuit Breaker (M.C.B.)
The supply cable should be at least equivalent to an ordinary PVC sheathed and
evice (R.C.D.) or an Earth Leakage Circuit Breaker (E.L.C.B.).
insulated min. 4 mm
o the electrical supply using a cable tted with an appropriately rated plug. The plug
Two-phase connection:
tted to the nal subcircuit in the xed wiring that is intended to supply the appliance.
The supply cable should be at least equivalent to an ordinary PVC sheathed and
insulated, min. 2.5 mm
between 2 and 3 should be removed, as shown. Failure to this will result in damage to
alent to an ordinary PVC sheathed and insulated, min. 4 mm
the appliance.
ble.
alent to an
. 2.5 mm
,
2
'3' should
will result
This appliance must be connected to a circuit which incorporates an isolating switch
providing full disconnection from the power supply.
If you raised the cooker to align it with the bench, make sure the base of the cooker
cannot slip.
Connecting the cable
1 Remove the cable access cover (lower right hand corner).
2 Provide a minimum of 1 metre of cable.
For 220-240 single phase operation, connect phase wire to terminal 1
(with links between 1-2 and between 2-3 fitted).
For 380-415V two phase operation, remove the link between 2-3 and connect phase 1
wire to terminal 1 (with link between 1-2 fitted); then connect phase 2 wire to
terminal 3.
3 Connect neutral wire to terminal 5 (with link between 4-5 fitted).
4 Connect ground wire to earth terminal
5 Replace cover; check that no conductors are trapped by the wiring cover.
INSTALLATION INSTRUCTIONS
, three-core (twin and earth), min. 1 m long flexible cable.
2
, four-core, min. 1 m long flexible cable. If fitted the bridging link
2
MODEL OR61S2L
MODEL OR61S2L
MODEL OR61S2CE
, three-core
2
Remove for two-phase
connection
.