electrical supply by a suitably registered person.
cause a safety hazard.
upply circuits must be disconnected. Failure to do so may result
Single phase connection:
cuit is protected by a suitably rated Miniature Circuit Breaker (M.C.B.)
The supply cable should be at least equivalent to an ordinary PVC sheathed and
●
●
evice (R.C.D.) or an Earth Leakage Circuit Breaker (E.L.C.B.).
insulated min. 4 mm
o the electrical supply using a cable tted with an appropriately rated plug. The plug
Two-phase connection:
tted to the nal subcircuit in the xed wiring that is intended to supply the appliance.
The supply cable should be at least equivalent to an ordinary PVC sheathed and
●
●
insulated, min. 2.5 mm
between 2 and 3 should be removed, as shown. Failure to this will result in damage to
alent to an ordinary PVC sheathed and insulated, min. 4 mm
the appliance.
ble.
alent to an
. 2.5 mm
,
2
'3' should
will result
This appliance must be connected to a circuit which incorporates an isolating switch
●
●
providing full disconnection from the power supply.
If you raised the cooker to align it with the bench, make sure the base of the cooker
●
●
cannot slip.
Connecting the cable
1 Remove the cable access cover (lower right hand corner).
2 Provide a minimum of 1 metre of cable.
For 220-240 single phase operation, connect phase wire to terminal 1
●
●
(with links between 1-2 and between 2-3 fitted).
For 380-415V two phase operation, remove the link between 2-3 and connect phase 1
●
●
wire to terminal 1 (with link between 1-2 fitted); then connect phase 2 wire to
terminal 3.
3 Connect neutral wire to terminal 5 (with link between 4-5 fitted).
4 Connect ground wire to earth terminal
5 Replace cover; check that no conductors are trapped by the wiring cover.
INSTALLATION INSTRUCTIONS
, three-core (twin and earth), min. 1 m long flexible cable.
2
, four-core, min. 1 m long flexible cable. If fitted the bridging link
2
MODEL OR61S2L
MODEL OR61S2L
MODEL OR61S2CE
, three-core
2
Remove for two-phase
connection
.