Lenovo G8124-E Installation Manual page 58

Rackswitch
Hide thumbs Also See for G8124-E:
Table of Contents

Advertisement

58
G8124-E Installation Guide
3. Set the new switch to use the Machine Type-Model (MTM) number of the old
unit. For example:
RS G8124-E (config)# boot mtm 1234-56X
New MTM value: 1234-56X
Please reset the system for the new changes to take effect
RS G8124-E(config)#
where 1234-56X is the MTM from your old unit.
Note: The MTM shown here is merely an example—use the actual MTM
recorded from your old G8124-E unit.
4. Set the new switch to use the serial number of the old unit. For example:
RS G8124-E (config)# boot esn 1000001
where 1000001 is the serial number of your old unit.
Note: The serial number shown here is merely an example—use the actual serial
number recorded from your old G8124-E unit.
5. Reset the switch using the following command:
RS G8124-E (config)# reload
6. When prompted for confirmation, enter y. The switch will then reboot.
7. After the switch reboots, return to the command prompt and verify that the VPD
information is correct using the following command:
RS G8124-E> show sys-info
System Information at 0:11:46 Wed Jan 6, 2015
Time zone: America/US/Pacific
Daylight Savings Time Status: Disabled
Lenovo RackSwitch G8124-E
Switch has been up for 0 days, 0 hours, 10 minutes and 45 seconds.
Last boot: 0:11:36 Wed Jan 6, 2015 (reset from console)
MAC address: fc:cf:62:9d:2b:00 IP (If 1) address: 192.168.49.50
Management Port MAC Address: fc:cf:62:9d:2b:fe
Management Port IP Address (if 4): 192.168.50.50
Hardware Part No: 00D9853
Switch Serial No: Y030PZ23H00E
Manufacturing date:12/12
MTM Value: 1234-56X
ESN: 1000001
...
For more information about using the switch interface, see the Application Guide
and Command Reference for your switch model and firmware version.