Olympia CM1830 Quick Reference

Olympia cash register user manual

Advertisement

Quick Links

Quick Reference
For more detailed information, please refer to the Operating Instructions manual.
Insert paper roll
Connect the cash register to the power supply. The message
issued. Press the
the paper rolls (37 mm width) for the receipt and journal in the paper holders. Do not use recycled paper. This causes
the printer to wear more quickly. Prepare the paper rolls for insertion. Unroll the first layer and cut the end of paper
straight. This prevents a paper jam occurring. The end of the paper rolls must be at the bottom. The journal paper must
be fed over the end of paper sensor as illustrated below. Insert the end of the paper roll, cut straight, into the printer
mechanism and press
Depending on the roll used, feed the paper past the tear-off edge on the printer lid or onto the paper reel. Close the
printer lid. Press the

Paper reel

The paper reel is required when the journal paper should be rolled onto it.
Change ribbon cassette
Note: Only use original ribbons.
Key-operated switch
The key should be set to position R (Registration) for normal operation.
Off
(normal operation)
Note: Loss of data and blocking of the cash register are possible in operating modes Z and P. Only use these
modes when you are familiar with programming and operating the cash register.
Olympia
09.2001
This quick reference only provides basic information.
key to stop the acoustic alarm. Open the printer lid. Set the key-operated switch to R. Insert
<
<
(receipt) or
key.
1. Open the printer lid.
2. Remove the paper reel.
3. Thread the end of the journal roll in the slit of the paper reel.
4. Insert the paper reel in the reel guides provided for it.
5. In order to remove the journal paper after it has been rolled up on the reel, remove
the paper reel and pull the journal paper roll off.
6. Reinsert the paper reel.
7. Close the printer lid.
1. Open the printer lid
2. Pull the ribbon cassette up and out using the grip provided.
3. Insert the new ribbon cassette in the printer so that the ribbon is positioned between
the print head and paper. Latch the ribbon cassette in place by pressing lightly.
4. Tighten the ribbon by turning the wheel in the direction of the arrow.
5. Close the printer lid.
Registrations
X-reports (without
memory deletion)
CM 1830 Cash Register
appears in the display and an acoustic signal is
¹º»
(journal) accordingly, until approx. 10 cm has been fed through.
Z-reports (with
memory deletion)
Page 1
5/621/3300 (13)
Programming
Training
All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CM1830 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Olympia CM1830

  • Page 1: Paper Reel

    The key should be set to position R (Registration) for normal operation. Registrations (normal operation) Note: Loss of data and blocking of the cash register are possible in operating modes Z and P. Only use these modes when you are familiar with programming and operating the cash register. Olympia 09.2001...
  • Page 2: Plu Registration

    Or: If items (PLUs) should be registered several times: Number of PLUs NNNN The sum of NNNN x PLU price is limited to the maximum capacity of the cash register. Conclude receipt After all the PLUs have been registered, press the...
  • Page 3 Enter: Display: ſ½ Enter: The basic cash register program is stored in the flags. Print flag settings: The programmed settings can be printed out Program flags: E.g. Flag 07, Time e.g. FLAG 01 VAT, DECPT Tax rate - Date format - Decimal places 3 2 = Recommended setting = Net price (excluding tax);...
  • Page 4 Password for Void, NS/#, Refund and PO keys 0 0 0 0 = No password / Password 0001 to 9999 FLAG 25 RESERVED Attempt no input! Cash register will be locked! FLAG 26 CHECKAMOUNT Highest acceptable check amount - compulsory entry 0 0 0 4 0 0 0 0 = Example for 400.00 pounds;...
  • Page 5 Cash register drawer open alarm signal 9 9 = Recommended setting 9 9 = Default setting, enter time in seconds. Alarm signal sounds after this interval if the cash register drawer remains open. Changing languages Note: Changing languages clears all the data and activates the default settings.
  • Page 6: Programming Tax Rates

    # QÃÃÃÃÃ # QÃÃÃÃÃÃÃÃ  e.g. # AÃÃÃÃÃ'  % # ÃÃÃÃÃÃ#"#A$$  %ÃÃÃÃÃÃÃÃÃÃ#r Olympia 09.2001 CM 1830 Cash Register FLAG 48 CODE-HEADER1 1st programmable language code for the press code 0 0 0 = Enter 3-digit press code FLAG 49 CODE-HEADER2...
  • Page 7: Programming Plus

    PLU price. Information on the price can also be replaced by zeros during manual programming. In this way, a publication need not be reprogrammed when the price changes. Olympia 09.2001 CM 1830 Cash Register Activate the group name program Enter the name for group 01.
  • Page 8: Programming Currency Conversion

    $ÃÃÃÃÃÃ#%#"#$ $ÃÃÃÃÃÃ Note: During programming (key-operated switch in Position: P), all the input can be corrected by pressing the Olympia 09.2001 CM 1830 Cash Register Activate the currency conversion program Enter the name, Define the conversion factor for EC card payments (FCE 1) Move to the next setting 1 = compulsory input;...
  • Page 9 Olympia 09.2001 CM 1830 Cash Register Refund Bold print Refund Bold print Refund appears in the display. Switch the cash register off immediately and º¸ÆÄ Page 9 First letter bold Space First letter bold Space 5/621/3300 (13) All rights reserved.
  • Page 10 The result exceeds the range The sum exceeds the range The counter for the validation printout exceeds the permissible value The total amount in the cash register drawer exceeds the permissible value Operating mode R/T has been changed Price input zero has been blocked...

Table of Contents