1. DESCRIPTION OF OPERATION
1.43

Sector Blank

You must prevent the transmission in some areas to protect passengers and crew
from microwave radiation. Also, if the reflections of echoes from the mast appear on
the screen, you must prevent the transmission in that area. You can set two sectors.
1. Press the MENU key to open the menu.
2. Use the Cursorpad ( or ) to select [Sector Blanks] and press the ENTER key.
3. Use the Cursorpad ( or ) to select [Sect-Blank 1 (or 2) Status] and press the
ENTER key.
4. Use the Cursorpad ( or ) to select [On] and press the ENTER key.
5. Use the Cursorpad ( or ) to select [Sect-Blank 1 (or 2) Start] and press the
ENTER key.
6. Use the Cursorpad ( or ) to set the start point of the sector and press the EN-
TER key.
7. Use the Cursorpad ( or ) to select [Sect-Blank 1 (or 2) End] and press the EN-
TER key.
8. Use the Cursorpad ( or ) to set the end point of the sector and press the EN-
TER key.
Note 1: You can not set the sector more than 180 degrees.
Note 2: You can not set the total width of sector 1 and sector 2 more than 270
degrees.
9. Press the MENU key to close the menu.
As shown in the following illustration, dashed lines mark the start and end points of the
sector.
1-52
Sect-Blank Status options
Sect-Blank Start setting window
Sect-Blank End setting window