Appendix A Troubleshooting; Main Status Indicator; Restoring The Okilan 6120I To Factory Defaults - Oki OkiLAN 6120i User Manual

Okilan network adapter user's guide 6120i
Hide thumbs Also See for OkiLAN 6120i:
Table of Contents

Advertisement

Appendix A
Troubleshooting

Main Status Indicator

Upon power-up, the main status indicator flashes
orange. It changes to green when the OkiLAN 6120i
passes self-test. The indicator stays orange if the
OkiLAN 6120i fails self-test. If the indicator turns
solid orange due to an error, a configuration sheet will
be printed automatically. Check the error message
reported on the configuration sheet.
Restoring the OkiLAN 6120i to
Factory Defaults
In most cases, the best way to restore the OkiLAN
6120i to factory defaults is via telnet. However, if you
are unable to connect to the device because of a
configuration error, use the following method which
does not require a network connection.
To restore the OkiLAN 6120i to factory defaults,
complete the following steps:
1. Power down the OkiLAN 6120i.
2. While holding in the Print Configuration Sheet
Test button, power up the OkiLAN 6120i. Hold the
button until the status indicator turns solid green.
3. Power cycle the OkiLAN 6120i. It will have
restored itself to defaults.
OKI OkiLAN 6120i User's Guide