The Led Indicators - AEI DK-9520 Programming & Installation Manual

Digital access control keypad

Advertisement

2) Programming
-- Set the above requirement into the keypad
0000 *
-------------------- System has been set in programming mode with the factory-set Master Code
8901 #
-------------------- System has been set for Multi User Mode** (please see NOTE (a) below)
0 3289 #
--------------- 3289 has been stored as the new Personal Master Code
1 01 8321 #
------ 8321 has been stored as the 1st User Code for door open
1 02 11223 #
--- 11223 has been stored as the 2nd User Code for door open
1 03 33221 #
--- 33221 has been stored as the 3rd User Code for door open
2 1 6854 #
---------- 6854 has been stored as Authorization Code for inhibit control
40 1 #
---------------------- Output Relay has been set to Momentary Mode, 1 second for door strike
51 #
--------------------------- Inhibit Authorization Control in Start / Stop Mode
72 10 #
------------------ The keypad has been set to lock during 15 minutes after 10 successive false
codes
*
------------------------------------ Keypad exits programming mode. All the above data are stored and ready for
use
NOTE:
a) **Enter the Multi User Mode Command Code "
already in Multi User Mode.
b) In case of wrong entry during programming, cancel it with
3) Operate The Keypad
-- Taking the data programmed above and other features in default values as reference
a)
To command output 1, enter any one of the User Codes in Group 1 and validate via the
8321 #
------ Output Relay activates for 1 second
11223 #
--- Output Relay activates for 1 second
33221 #
--- Output Relay activates for 1 second
b)
To command Authorization Control, enter the Authorization Code and validate via the
6854 #
------ Authorization Control Start / Stop
c)
The Personal Master Code is a Super User Code to command the relay output and also make operation
authorization control as like an authorization code for the keypad. This feature allows the owner to use
only one code to operate two functions. Enter the Personal Master Code and validate via
corresponding function code.
3289 #1
--- Output Relay activates for 1 second
3289 #2
--- Authorization Control Start / Stop (if programmed)
d)
The Accelerated Code is the First Two Digits of the User code(s). If the Relay Output has been programmed
in Start / Stop mode with Accelerated Code (Programming Option 42), it is possible to activate the Relay
Output with only the First Two Digits of the User Code(s). Deactivating of the Output always requires the
composition of the Complete User Code(s).
Example:
Output Relay has been re-programmed to Start / Stop Mode with Accelerated Code (Programming Option
42) with the Complete Code of 1st User Code in Group 1:
2nd User Code in Group 1:
83 #
------------- Output Relay starts
8321 #
------ Output Relay stops
11 #
------------- Output Relay starts
11223 #
--- Output Relay stops
&
Super User Code
8901"
may not be necessary if the keypad was
#
key, or, wait 10 seconds, then re-try.
#
key
#
key
#
8321
The Accelerated Code is:
11223
The Accelerated Code is:
11
10

THE LED INDICATORS

!
RED
(INHIBIT)
It lights up if the operation of output relay is inhibited. Please see "Door Lock Inhibit Authorization" for more
details.
!
AMBER
(MAINS)
This is a status indicator. Its signal is in synchronization with the pacifier tones from the built-in buzzer.
see the Chart below for the indication details.
!
GREEN
(DOOR)
It lights up during the time that output relay is active.
THE PACIFIER TONES & THE LED INDICATING SIGNALS
The built-in buzzer and the amber LED indicator give the following tones and signals for operation status:
STATUS
1. In programming mode
2. Successful key entry
3. Successful code entry
4. Unsuccessful code entry
5. DAP jumper not replaced
6. In standby mode
7. Output relay activated
NOTE: *
All Pacifier Tones can be enabled or disabled through programming options at Location 83.
**
The Output Activation Beep can be enabled or disabled through programming options at Location 81.
THE DAP JUMPER D
If the Personal Master Code is forgotten, use the DAP jumper to override the forgotten code permitting the keypad
direct entry into programming mode. You are required to apply the following procedures precisely.
and the
1.
Disconnect power supply.
2.
Displace the DAP jumper from OFF to ON position.
3.
Reconnect power supply (buzzer is activated).
Put the DAP jumper back to OFF position (this done, the buzzer is de-activated).
4.
5.
The keypad is in programming mode and ready to receive new programming data.
6.
As the old master code was forgotten, suggest you to put a 4 digit new master code into Location 0 first.
7.
Enter the new programming data starting from Section (B) in the summary chart shown below.
83
THE FACTORY-SET MASTER CODE --
For the owner's convenience in programming at the first time, the factory has put a Master Code 0000 into the
keypad. To compromise security, in all cases, the owner should program a Personal Master Code to invalidate the
factory-set Master Code before use.
TONES F
- - -
1 Beep
2 Beeps
5 Beeps
Continuous Beeps
- - -
1 second Long Beep
FF
( IRECT
A
CCESS TO
P
ROGRAMMING)
IMPORTANT NOTE
3
Please
LED SIGNALS
ON
1 Flash
2 Flashes
5 Flashes
Continuous Flashes
1 Flash in 2 seconds interval
- - -

Advertisement

loading