Download Print this page

AEI DK-9520 Programming & Installation Manual page 4

Digital access control keypad

Advertisement

PROGRAMMING OPTIONS --
SUMMARY CHART
A) Use The Factory-set Master Code to Entry in Programming
Entry of Code
Validation
Comments
0000
*
Set system into Programming Mode with the Factory-set Master Code
B) Set System to Single User or Multi User Mode & Refresh The System
User Mode Options Validation
Comments
8900
#
Set system to Single User Mode, clear all the data previously stored and refresh system
8901
#
Set system to Multi User Mode, clear all the data previously stored and refresh system
C) Recording of Personal Master Code
&
i) Recording of the master code and user codes for Single User
Locations
Entry of Codes
Validation
0
#
4 digits, fixed
1
#
4 digits, fixed
2
#
4 digits, fixed
ii) Recording of the master code and user codes for Multi-User (Digits may be repeated)
Locations
User Number Entry of Codes
0
4 to 8 digits
1
00 to 99
4 to 8 digits
2
0 to 9
4 to 8 digits
D) Configuration of Output Modes
--
Installer Programming
Locations
Code of Duration
Validation
Comments
40
#
1 to 999
Output relay in Momentary Mode from 1 to 999 seconds
41
#
Output relay in Start / Stop Mode (toggle)
42
#
Output relay in Start / Stop Mode (toggle) with accelerated code
50
#
1 to 999
Authorization Control from 1 to 999 seconds
51
#
Authorization Control in Start / Stop Mode (toggle)
52
#
Authorization Control in Start / Stop Mode (toggle) with accelerated code
--
When starts for the first time
--
Installer Programming
User Codes
-- User Programming
(Digits may be repeated)
Comments
Personal Master Code & Super User Code
User Code for relay output for door open
Authorization Code for door lock operation inhibit contol
Validation Comments
#
Personal Master Code & Super User Code
#
100 User Codes in Group 1 for relay output for door
open, user number from 00 to 99
#
10 Authorization Codes for door lock operation inhibit
control
4
NOTE:
a) **Enter the Single User Mode Command Code "8900" may not be necessary if the keypad was
already in Single User Mode.
b) In case of wrong entry during programming, cancel it with
3) Operate The Keypad
-- Taking the data programmed above and other features in default value as reference
a)
To command an output, only enter its user code. Press
8321
----------- Output Relay activates for 1 second
6854
----------- Authorization Control Start or Stop
b)
The Personal Master Code is a Super User Code to command the relay output and also make operation
of authorization control as like an authorization code for the keypad. This feature allows the owner to use
only one code to operate two functions. Enter the Personal Master Code and validate via
corresponding function code.
3289 #1
--- Output Relay activates for 1 second
3289 #2
--- Authorization Control Start / Stop (if programmed)
c)
The Accelerated Code is the First Two Digits of the User Code. If Output Relay has been programmed in
Start / Stop mode with Accelerated Code at Location 42, it is possible to activate the Output Relay with
only the First Two Digits of the User Code. Deactivating of the Output Relay always requires the
composition of the Complete User Code.
Example:
Output Relay has been re-programmed to Start / Stop Mode with Accelerated Code (Location:
42) with the Complete Code of:
83 #
-------------
Output Relay starts
8321
-----------
Output Relay stops
d)
Try to put some random false codes to the keypad to test its Safety. The keypad considers 4 digits as
one code and it generates 5 beeps for each unsuccessful code entry. The keypad locks itself during 15
minutes after 10 successive false codes. Normal operation will be resumed after 15 minutes expired, or,
it can be reset with the Master Code during the locking period.
3289 #
------ Locking is reset and keypad resumes normal operation
C) MULTI-USER MODE OPERATION -- An Example
1) Re uirement
q
a) Multi-User Mode Operation
b) Change the factory-set Master Code 0000 to a Personal Master Code 3289
c) Set 1st User Code of 8321 for door open
d) Set 2nd User Code of 11223 for door open
e) Set 3rd User Code of 33221 for door open
f ) Set an Authorization Code of 6854 for inhibit control
g) Set Output Relay to Momentary Mode, 1 second for door strike
h) Set Inhibit Authorization Control in Start / Stop Mode
i ) Set the keypad to lock itself during 15 minutes after 10 successive false codes
#
key, or, wait 10 seconds, then re-try.
#
is NOT required.
8321
The Accelerated Code will be:
83
.
9
#
and the

Advertisement

loading