Download Print this page

AEI DK-9520 Programming & Installation Manual page 5

Digital access control keypad

Advertisement

PROGRAMMING AND USE OF THE KEYPAD --
A) PROCEDURES OF PROGRAMMING
a)
All programming is accomplished entirely from the front of the keypad. The keypad may be programmed in
your shop or at the installation site. Programmed information is stored in non-volatile memory so it will not
be lost if power is removed.
b)
When programming is required. It is necessary to set the keypad into programming mode first with the
master code and validating it with
key.
MASTER CODE
NOTE:
If the master code is forgotten, please use DAP jumper to set the keypad into programming mode.
See DAP JUMPER description in previous section for the details.
c)
After the keypad is in programming mode, you may go to any Location for your programming options one by
one, please see Programming Options Summary Chart for the feature details.
d)
You may make continuous programming until all desired options are programmed. Repeated programming at
the same Location is allowed if the previous entry was mistaken.
LOCATION 1
OPTION
I
I
LOCATION n
OPTION n
e)
Exit programming mode with the
key after all your required options are programmed. The new information
that you have just programmed is saved.
B) SINGLE USER MODE OPERATION -- An Example
1) Re uirement
q
a ) Single User Mode Operation
b ) Change the factory-set Master Code 0000 to a Personal Master Code 3289
c ) Set User Code of 8321 for door open
d ) Set an Authorization Code of 6854 for inhibit control
e ) Set Output Relay to Momentary Mode, 1 second for door strike
f ) Set Inhibit Authorization Control in Start / Stop Mode
g ) Set the keypad to lock itself during 15 minutes after 10 successive false codes
2) Programming -- Set the above requirement into the keypad:
------- System has been set in programming mode with the factory-set Master Code
------- System has been set for Single User Mode** (please see NOTE (a) below)
-- 3289 has been stored as the new Personal Master Code
-- 8321 has been stored as User Code, for door open
-- 6854 has been stored as Authorization Code for inhibit control
--------- Output Relay has been set to Momentary Mode, 1 second for door strike
-------------- Inhibit Authorization Control in Start / Stop Mode
----- The keypad has been set to lock during 15 minutes after 10 successive false codes
----------------------- Keypad exits programming mode. All the above
OPERATION EXAMPLES
&
Super User Code
data
are stored and ready for use
8
E) Personal Safety
--
Installer Programming
Locations
No. of False Entry Validation Comments
5 to 10
00
F) Output Activation Announcer
--
Installer Programming
Locations
Code of Functions Validation
Comments
1 second notifying beep is given to notify the person outside to open the
door when output relay is activated with an user code or egress button.
Good for the locking device that gives no sound when it activates, such
as a magnetic lock.
Notifying beep disabled and replaced by 2 short successful code entry
beeps for valid user codes
G) User Code Entry Mode (Auto or Manual)
Locations
Code of Functions Validation
Comments
Auto Entry Mode is selected.
required in code entry. The User Codes MUST be set in the same digit
length as the Master Code in Auto Entry Mode and the code length can
be 4-8 digits
Manual Entry Mode is selected.
required in code entry. The user codes can be 4-8 digits and they are
not required to be in the same length as the Master Code
NOTE:
In Single User Mode, no matter the selection is Auto or Manual mode, the Master Code and the User Code
MUST be set in the length of 4 digits.
H) Pacifier Tones (Keypress Acknowledgement Tones)
Locations
Code of Functions Validation
Comments
Pacifier tones available on keypress
All pacifier tones are inhibited. Good for place requires silent environment
I) Main LED Flashing ON-OFF -- Installer Programming
Locations
Code of Functions
Validation
Comments

Main LED flashing in normal mode during system standby

Main LED OFF during system standby
J) Exit Programming Mode
Validation
Comments
Keypad exits programming mode and returns to normal operation
After 10 successive false codes, the keypad locks during 30 seconds
After 10 successive false codes, the Duress output switches to ground
Selectable of after 5 to 10 successive false codes, the keypad locks
during 15 minutes. The keypad can be reset to release locking with
the Master Code at any time during the locking period
Disappearance of all the above securities
--
Installer Programming
key that follows the user code is NOT
key that follows the user code is
--
Installer Programming
5