SINGLE USER MODE OR MULTI-USER MODE SELECTION
The keypad consists two sets of software for owner's selection in user code programming. They are "Single User
Mode" and "Multi-User Mode".
The keypad has been set with a Master Code of "0000" and in Single User Mode at the factory. If your required
mode is Multi-User, you have to refresh the system with the appropriate comment code, 8901, to set it into Multi-
User Mode.
Single User Mode (Command Code: 8900)
Single User Mode is prepared for the simple users, which allows only one user code to operate the output relay.
The user codes are fixed to 4 digits and 10,000 code combinations are possible. User code can be programmed
directly into the User Code Location 1. Please see Programming Summary Chart Section (C), item i) for details.
This mode is always set with Auto Code Entry in default. The user does not require to press the
code entry. The user only needs to enter the 4 digit user code. The relay will activate for the programmed time.
NOTE:
The system can be set for Manual Entry with programming option 0 at Location 82 if required.
Multi-User Mode (Command Code: 8901)
Multi-User Mode allows up to 100 individual user codes to operate the output relay. The user codes can be 4 to 8
digits with over 100 million code combinations. The user codes can be set for Auto Entry or Manual Entry with
programming options at Location 82. As Manual Entry Mode is in default. The user code followed by
required.
Once the keypad is programmed in Auto Entry, the Master Code and the User Codes MUST be set in the same digit
length, and the need for the user code not to be followed by
The Default Values
Default Values
Comments
401
Output Relay in 1 second Momentary Mode
70
After 10 successive false code, the keypad locks during 30 seconds
811
Output relay activation beep ON
820
User code Manual Entry Mode
821
User code Auto Entry Mode
831
Pacifier Tones ON
841
Main LED flashing in normal mode during system standby
NOTE: **
The default values in Multi-User Mode and Single User Mode are exactly the same except the User Code
Entry Mode.
Code Entry Limitation in Multi-User Mode due to Duress Code
This simplified version of keypad comes without Duress function but the system was designed to set up the Duress
Code by itself automatically with the first digit of the User Code "+2". To prevent the other User Codes fall into the
Duress Code, or the Duress Codes fall into other User Codes, the first digit of a "Stored" User code "+2" or "-2" is
not allowed for the later User Code entry in programming. The system will refuse those code entries.
For example:
An User Code 56789 was stored in the system, then 36789 and 76789 are not allowed for other
User Codes.
SET THE SYSTEM TO SINGLE USER MODE
The system can be set to Single User Mode with the command code "
system is refreshed for other mode. Make sure that the Master Code was already in 4 digits before setting the
system to Single User Mode.
MASTER CODE
-----
Single User Mode on Duty (please wait 2-3 seconds until the confirmation
beeps are heard after the
key is required.
**
(For Multi-User Mode)
**
(For Single-User Mode)
8900"
and will stay in that mode until the
key is pressed)
6
SET THE SYSTEM TO MULTI-USER MODE
The system can be set to Multi Users Mode with the command code "
system is refreshed for other mode.
MASTER CODE
REFRESH THE SYSTEM
The system can be changed from Single User Mode to Multi-User Mode; or vice versa with the above operation
command codes.
key in user
When this is done, the keypad will reset itself as a fresh unit with the default values; and all the programmed data
that stored previously will be cleared except the Master Code.
IMPORTANT NOTES:
1)
Make sure the User Code, Authorization Code and Master Code are in the length of 4 Digits if the system is in
Single User Mode operation. Otherwise, code entry will not be accepted.
2)
It is necessary to change the Master Code in the length of 4 digits first (no matter it was in 4 digits or more
key is
than 4 digits in Multi- User Mode) before refreshing it from Multi-User Mode to Single User Mode.
3)
The system takes approximate 2 to 3 seconds to refresh itself for the new operation mode after the command code
is entered. DO NOT enter any code during the system is being refreshed until the 2 confirmation beeps are heard.
DOOR LOCK INHIBIT AUTHORIZATION
This is an optional feature of the system. An authorization code can be set up for the keypad to control its
operation. The owner may key in the code to temporarily stop the electric lock in the night time or after office hour
with nobody inside the house to prevent unauthorized access.
The authorization code is for disabling or enabling the operation of the keypad output. The Red LED is ON for
keypad output disabled and it is OFF while the keypad is in normal manner for door strike.
The following are the procedures of setting up the authorization code:
1)
Set system in Programming Mode
MASTER CODE
2)
Set an Authorization Code of your own
a)
If in Single User Mode (The Authorization code is 4 digits)
AUTHORIZATION CODE
4 DIGITS
b)
If in Multi-User Mode (The Authorization code can be 4-8 digits)
AUTHORIZATION CODE
3)
Set the Authorization Code in Start / Stop Mode
4)
End of Programming
-----
Multi-User Mode on Duty (please wait 2-3 seconds until the confirmation beeps
are heard after the
key is pressed)
--
WHEN IN CHANGE OF OPERATION MODE
4-8 DIGITS
7
8901"
and will stay in that mode until the
WARNING
F O R S A F E T Y, M A K E S U R E
NOBODY INSIDE THE HOUSE
BEFORE YOU START THE DOOR
LOCK INHIBIT FUNCTION. THE
LOCK LOCKS ALL THE TIME
DURING "INHIBIT" IS ON DUTY.
THE INHIBIT AUTHORIZATION
CODE SHOULD ALWAYS BE KEPT
BY THE OWNER BUT NOT OTHER
USER(S).

Advertisement

loading