(2)
Window list data: DATA OUT phase (Initiator to Target)
The window list data parameter specifies the window ID for scanner reading. The
scanner supports the following.
a. Simplex reading specification
Transfer length = 1
Window list data
Byte 0 Window ID=0
b. Duplex reading specification
Transfer length = 2
Window list data
Window ID=0
Byte 0
1
Window ID=128
If any other combinations are specified, the following errors are returned:
-
Status: B'00001' (Check condition)
-
Sense key: X'5' (Illegal request)
(3)
Operation
When the SCAN command is received, the reading method is defined for the
scanner.
4 $ 109