Disassembly & Assembly Procedure - Hitachi RAF-25FX8 Service Manual

Room air conditioner
Table of Contents

Advertisement

Available languages

Available languages

DISASSEMBLY & ASSEMBLY PROCEDURE
1. AIR FILTER
Clean the air filter, as it removes dust inside the room.
Be sure to clean the filter once every two weeks so as not to consume electricity unnecessarily.
PROCEDURE
1
Open the front panel.
• To open the front panel, use the remote controller to stop unit
operation. Then press at the top left and right corners of the front
panel.
• Grasp the left and right sides of the front panel and open it toward you.
2
Remove the filters.
(Front side 2 pieces, upper side 2 pieces, total 4 pieces.)
3
Remove dust of the filters using a vacuum cleaner.
• After using neutral detergent, wash with clean water and dry in
shade.
4
Attach the filters.
• Attaching the filters.
(Front side 2 pieces, upper side 2 pieces, total 4 pieces.)
5
Close the front panel.
• To close the front panel, press at the top left and right corners of the
front panel.
• Press the upper center part of the front panel to close properly.
2. HOW TO INSTALL AND REMOVE THE FRONT PANEL
• Be sure to use both hands to grasp the front panel when removing it or attaching it.
• The front panel may be installed up or down to suit user preference.
Removing
① Press the hook found at the tip of the resin band
installed inside the front panel's right section to
remove the resin band.
Attaching
① Attach three front panel bearings to the axis of
the front cover. (Set the hook to face up.)
② Pull the front panel down toward you and once
Front cover
Resin band
Hook
Front panel
② Insert the tip of the resin band into the hole of the
Upper side filter
fully open, pull it to remove.
protrusion inside the right section of the front
panel.
– 80 –
Front side filter
Resin band

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rac-25fx8Raf-35fx8Rac-35fx8

Table of Contents