MODE D'ECLAIRAGE DU VOYANT D'AUTO-DIAGNOSTIC
MODÈLE RAC-25FX8, RAC-35FX8
IPM
BLOC D'ALIMEN-
TATION INTELLIGENT
LAMPES AUTO-DIAGNOSTIC
MODE D'ALLUMAGE AUTO-DIAGNOSTIC
COUPEZ L'ALIMENTATION
ÉLECTRIQUE ET ATTENDEZ
PLUS DE 10 MINUTES
AVANT D'EFFECTUER LE
TRAVAIL DE MAINTENANCE
VÉRIFIEZ LA TENSION CC
AU POINT DE MESURE
INDIQUÉ SUR LA FIGURE:
IL DOIT ÊTRE INFÉRIEUR À
10 V
NE TOUCHEZ PAS AUX
AUTRES COMPOSANTS
LORSQUE VOUS UTILISEZ
LE COMMUTATEUR DE
MAINTENANCE
OPÉRATION DE MAINTENANCE
PROCÉDURE DE RÉFRIGÉRATION, POMPE
ARRÊTÉE OU OPÉRATION INDÉPENDANTE DE
1 FOIS
L'UNITÉ EXTÉRIEURE
1. METTEZ L'APPAREIL HORS TENSION ET
REMETTEZ-LE SOUS TENSION.
2 FOIS
2. ATTENDEZ AU MOINS 1 MINUTE.
3. APPUYEZ SUR LE COMMUTATEUR DE
MAINTENANCE (SUR LE C.I.) PENDANT
3 FOIS
PLUS DE 1 SECONDE.
L'OPÉRATION DE MAINTENANCE DÉMARRE.
POUR ARRÊTER CETTE OPÉRATION, APPUYEZ
À NOUVEAU SUR LE COMMUTATEUR DE
4 FOIS
MAINTENANCE (PENDANT PLUS DE 1
SECONDE).
POUR RELANCER LE FONCTIONNEMENT
5 FOIS
NORMAL, COUPEZ ET RALLUMEZ À NOUVEAU
LA SOURCE D'ALIMENTATION.
AFIN DE PROTÉGER LE COMPRESSEUR
6 FOIS
D'ÉVENTUELS DOMMAGES, NE PAS FAIRE
FONCTIONNER L'APPAREIL PENDANT PLUS DE
5 MINUTES AVEC LA VANNE DE MAINTENANCE
FERMÉE.
7 FOIS
8 FOIS
9 FOIS
10 FOIS
12 FOIS
13 FOIS
: ALLUMÉ
NOM AUTO-
D É T A I L S
DIAGNOSTIC
PENDANT LE FONCTI O NNEMENT
LD303 (ROUGE) S' A LLUME
FONCTIONNEMENT
FONCTIONNEMENT
NORMAL
COMPRESSEUR
VALEUR
SURCHARGE
RÉGLÉE
DURÉE
SURCHARGE
LA VITESSE DE ROTATION EST
CONTRÔLÉE AUTOMATIQUEMENT
POUR PROTÉGER LE
SURCHARGE
COMPRESSEUR EN CAS DE
SURCHARGE
PENDANT L'ARRÊT
LD303 (ROUGE) S'ÉTEINT
ARRÊTÉ PAR LE THERMOSTAT
ARRÊT NORMAL
OU LE CONTRÔLEUR
RÉINIT. DU MICROPROCESSEUR
ARRÊT
(NORMAL QUAND LE COMMUT.
RÉINIT.
M/A A ÉTÉ MIS SUR MARCHE)
COUPURE
LE COURANT DE CRÊTE DU
COURANT DE
COMPRESSEUR A DÉPASSÉ LA
CRÊTE
LIMITE MAXIMUM
ROTATION
POSITION DU ROTOR DE
BASSE VITESSE
COMPRESSEUR PERDUE
ANORMALE
ÉCHEC DE COMMUTATION DE
ÉCHEC DE
DÉMARRAGE SYNC. BASSE FRÉQUENCE
COMMUTATION
SUR POSITION DE DÉTECTION
COUPURE LIMITE
FONCTION DE PROTECTION ANTI-SURCHARGE
INFÉRIEURE
DEMANDE UNE VITESSE INFÉRIEURE À LA
SURCHARGE
VITESSE MINIMUM DU COMPRESSEUR
SURCHAUFFE COMPRESSEUR
AUGM. TEMP.
DÉTECTÉE PAR OH
OH THEMISTOR
THERMISTANCE.
VALEUR ANORMALE
THEMISTOR
THEMISTOR (OUVERT OU
ANORMAL
COURT-CIRCUIT) DÉTECTÉE.
PAS D'ACCÉLÉRATION SUPÉRIEURE
ÉCHEC
À LA VITESSE MINIMUM POUR LE
D'ACCÉLÉRATION
COMPRESSEUR.
COMMUNICATION ENTRE UNITÉ
ERREUR DE
INTÉRIEURE ET UNITÉ
COMMUNICATION
EXTÉRIEURE INTERROMPUE
SOURCE
SOURCE D'ALIMENTATION
D'ALIMENTATION
ANORMALE DÉTECTÉE
ANORMALE
ERREUR DE
RÉGIME VENTILATEUR
BLOCAGE DE
EXTÉRIEUR N'ATTEINT PAS LA
VENTILATEUR
VALEUR PRÉVUE
EEPROM:
LE MICRO-ORDINATEUR NE PEUT
ERREUR DE
LIRE LES DONNÉES DE LA
LECTURE
MÉMOIRE MORTE (EEPROM)
EXEMPLE DE
CLIGNOTEMENT (5 FOIS)
COMMUTATEUR DE MAINTENANCE
– 167 –
: CLIGNOTE : ÉTEINT
POI N T DE CONTRÔLE
PRI N CI P AL
PAS UN DYSFONCTIONNEMENT
INDIQUE UN ÉTAT DE PROTECTION
DE SURCHARGE
PAS UN DYSFONCTIONNEMENT
PAS UN DYSFONCTIONNEMENT
C.I. D'ALIMENTATION
C.I. PRINCIPAL
C.I. PRINCIPAL
COMPRESSEUR
C.I. D'ALIMENTATION
C.I. PRINCIPAL
COMPRESSEUR
C.I. D'ALIMENTATION
C.I. C.I. PRINCIPAL
COMPRESSEUR
C.I. D'ALIMENTATION
L'UNITÉ EXTÉRIEURE EST EXPOSÉE À LA LUMIÈRE
DIRECTE DU SOLEIL OU SON FLUX D'AIR EST BLOQUÉ.
MOTEUR DE VENTILATEUR
C.I. PRINCIPAL
LA TENSION EST EXTRÊMEMENT BASSE.
FUITE DE FLUIDE FRIGORIGÈNE
COMPRESSEUR
CIRCUIT OH THEMISTOR
(C.I. PRINCIPAL)
THEMISTOR
BRANCHEMENT DU THEMISTOR DÉFECTUEUX
CIRCUIT THERMISTANCE
FUITE DE FLUIDE FRIGORIGÈNE
COMPRESSEUR
CÂBLE MAL BRANCHÉ.
CÂBLE OUVERT.
CIRCUIT D'INTERFACE ENTRE
SOURCE D'ALIMENTATION ANORMALE
CÂBLE MAL BRANCHÉ
C.I. D'ALIMENTATION
C.I. PRINCIPAL
MOTEUR DE VENTILATEUR
CIRCUIT MOTEUR VENTILATEUR
C.I. PRINCIPAL
S'ALLUME PENDANT 0,25
SEC À DES INTERVALLES
DE 0,25 SEC.