NO. 0423E RAF-25QH8 RAF-35QH8 SERVICE MANUAL RAF-50QH8 REFER TO THE FOUNDATION MANUAL TECHNICAL INFORMATION FOR SERVICE PERSONNEL ONLY CONTENTS SPECIFICATIONS ------------------------------------------------------------------- 5 HOW TO USE ------------------------------------------------------------------------ 6 INDOOR UNIT CONSTRUCTION AND DIMENSIONAL DIAGRAM --------------------- 27 MAIN PARTS COMPONENT --------------------------------------------------- 28...
Page 32
MODEL RAF-25QH8/RAF-35QH8/RAF-50QH8 – 33 –...
Page 33
MODEL RAF-25QH8/RAF-35QH8/RAF-50QH8 – 35 –...
Page 34
MODEL RAF-25QH8/RAF-35QH8/RAF-50QH8 Combination of operations: When operation mode is selected: One unit Other unit During automatic operation: Cooling • You cannot operate the indoor units in the following combinations. • When heating operation is automatically selected for the first indoor unit, the next...
Page 35
Table 1 Fan speed by mode MODEL RAF-25QH8 RAF-35QH8 RAF-50QH8 Operation mode Fan speed mode Label name PROM LABEL REQUIRED VALUE REQUIRED VALUE REQUIRED VALUE FWSS_M Ultra Lo NAME OF UNIT SIDE OF UNIT SIDE OF UNIT SIDE Silent, Sleep FWSOY_M –1...
Page 36
Fan tap is controlled from outdoor unit. Compressor speed is determined by instruction sent from indoor unit and corrected by outdoor unit according to such factors as capacity, fan speed, number of units being operated, outdoor temperature, etc. If another indoor unit is doing heating operation, cooling operation cannot be done. –...
Page 39
Hot Dash is started when the operation is started at fan speed “AUTO” of “HI” or when the fan speed is changed to “AUTO” or “HI” during heating operation, and when the compressor speed (P item) reaches (WMAX1 or WMAX2) or higher with the room temperature at 18°C or less and outdoor temperature at 10°C or less.
Page 55
When only the power switch is turned To ensere correct opening and closing of the deflector on, the deflector and the upper louver and the upper louver will move when power is turned at the bottom air outlet moves even if on or the unit is to be operated in order to check its the START/STOP button is not fully opened and closed positions.