Hitachi RAF-35NH5 Instruction Manual

Indoor unit
Hide thumbs Also See for RAF-35NH5:

Advertisement

SPLIT TYPE AIR CONDITIONER
Instruction manual
To obtain the best performance and ensure years of
trouble free use, please read this instruction manual
completely.
Bedienungsanleitung
Bitte lesen Sie diese Bedienungsanleitung aufmerksam
durch, um durch richtige Bedienung jahrelangen und
störungsfreien Betrieb zu gewährleisten.
Mode d'emploi
Des performances optimales et un fonctionnement à
long terme seront assurés en appliquant les présentes
instructions après avoir entièrement lu ce mode
d'emploi.
Manuale di istruzioni
Per garantire la migliore prestazione e la più lunga
durataleggere attentamente e al completo le seguanti
istruzioni.

INDOOR UNIT

MODEL
RAF-25NH5
RAF-35NH5
RAF-50NH5
INDOOR UNIT
Page 1~22
Seite 23~44
Page 45~66
Pag. 67~88
RAF-25NH5
RAF-35NH5
RAF-50NH5
Manual de instrucciones
Para obtener el mejor funcionamiento y asegurar años
de uso libre de problemas, lea cuidadosamente este
manual de instrucciones.
Manual de instruções
A fim de obter um bom funcionamento e de garantir
uma utilização sem falhas durante muitos anos, é favor
ler este manual de instruções completamente.
O‰ËÁ›Â˜ ¯Ú‹Ûˆ˜
°È¿ Ó· Â›Ó·È ÂÁÁ˘Ë̤ÓË Ë Î·Ï‡ÙÂÚË ‰˘Ó·Ù‹ ÏÂÈÙÔ˘ÚÁ›·
Î·È Ë ¯ˆÚ›˜ ‚Ï¿‚˜ Ì·ÎÚÔÚfiıÂÛÌË ¯Ú‹ÛË Ù˘
Û˘Û΢‹˜, ‰È·‚¿ÛÙ fiϘ ÙȘ οوıÈ Ô‰ËÁ›Â˜.
àÌÒÚÛ͈Ëfl ÔÓ ˝ÍÒÔÎÛ‡Ú‡ˆËË
ÑÎfl o·ecÔe˜eÌËfl ÌaËÎyÛ¯Ëx ˝ÍcÔÎyaÚaˆËoÌÌ˚x
xapaÍÚepËcÚËÍ Ë ÏÌo„oÎeÚÌeÈ ·eÁoÚÍaÁÌoÈ pa·oÚ˚
o·opy‰o‚aÌËfl Ìeo·xo‰ËÏo ÔoÎÌocÚ¸˛ oÁÌaÍoÏËÚ¸cfl
c ‰aÌÌoÈ àÌcÚpy͈ËeÈ Ôo ˝ÍcÔÎyaÚaˆËË.
˚
CH
Página 89~110
Página 111~132
ÛÂÏ›‰· 133~154
ÒÚ. 155~177

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi RAF-35NH5

  • Page 1: Indoor Unit

    SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAF-25NH5 RAF-35NH5 RAF-50NH5 INDOOR UNIT RAF-25NH5 RAF-35NH5 ˚ RAF-50NH5 Instruction manual Manual de instrucciones Page 1~22 Página 89~110 To obtain the best performance and ensure years of Para obtener el mejor funcionamiento y asegurar años...
  • Page 2: Safety Precaution

    SAFETY PRECAUTION • Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit. • Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly.
  • Page 3 PRECAUTIONS DURING OPERATION • The product shall be operated under the manufacturer specification and not for any other intended use. PROHIBITION • Do not attempt to operate the unit with wet hands, this could cause fatal accident. DON'T WET • When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
  • Page 4: Multi-Air Conditioner

    Vertical air deflector (Air outlet) Air filter Signal receiver Front panel (Air intake) Vertical air deflector (Air outlet) Remote controller MODEL NAME AND DIMENSIONS MODEL WIDTH HEIGHT DEPTH RAF-25NH5 RAF-35NH5 750mm (29-17/32") 600mm (23-5/8") 215mm (8-15/32") RAF-50NH5 (INDOOR UNIT) – 4 –...
  • Page 5: Indoor Unit Indicators

    INDOOR UNIT CONTROL PANEL TEMPORARY SWITCH If the remote controller does not work due to battery failure, TEMPORARY SWITCH press this switch to start and stop operation. • This temporary operation will be at the most recent setting made. (The unit will immediately go into automatic operation once power is switched on.) AIR OUTLET SWITCH AIR OUTLET SWITCH IS SET TO...
  • Page 6: Remote Controller

    NAMES AND FUNCTIONS OF EACH PART REMOTE CONTROLLER • This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
  • Page 7: Automatic Operation

    VARIOUS FUNCTIONS I Auto Restart Control • If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode and airflow direction. (As the operation is not stopped by remote controller.) • If you intend not to continue the operation when the power is resumed, switch off the power supply. When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and airflow direction.
  • Page 8: Heating Operation

    HEATING OPERATION • Use the device for heating when the outdoor temperature is under 21°C. When it is too warm (over 21°C), the heating function may not work in order to protect the device. • In order to keep reliability of the device, please use this device above -15°C of the outdoor temperature. Press the FUNCTION selector so that the display indicates (HEAT).
  • Page 9: Dehumidifying Operation

    DEHUMIDIFYING OPERATION Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work. Press the FUNCTION selector so that the display indicates (DEHUMIDIFY). The FAN SPEED is set at LOW automatically. The FAN SPEED button does not work.
  • Page 10: Cooling Operation

    COOLING OPERATION Use the device for cooling when the outdoor temperature is –10~42°C. (Only RAM-80QH5: 10~42°C) If humidity is very high (over 80%) indoors, some dew may form on the air outlet grille of the indoor unit. Press the FUNCTION selector so that the display indicates (COOL).
  • Page 11: Fan Operation

    FAN OPERATION You can use the device simply as an air circulator. Use this function to dry the interior of the indoor unit at the end of summer. Press the FUNCTION selector so that the display indicates (FAN). Press the (FAN SPEED) button.
  • Page 12: How To Set The Timer

    HOW TO SET THE TIMER Set the current month and day Time, Day, Month TIME, DAY, with the TIMER control button. After you change the MONTH (current batteries; time, day, month) OFF TIMER ON TIMER Press the (OFF-TIMER) OFF-Timer button. The (OFF) mark blinks on RESERVE the display.
  • Page 13 Set the Set the current time with Press the (TIME) button (TIME) button. the TIMER control button. again. The time indication starts • The time indication will lighting instead of flashing. disappear automatically in 10 seconds. • To check the current time setting, press the (TIME) button twice.
  • Page 14: How To Set The Sleep Timer

    HOW TO SET THE SLEEP TIMER Set the current time at first if it is not set before (see the pages for setting the current time). Press the (SLEEP) button and the display changes as shown below. Mode Indication 1 hour 2 hours 3 hours 7 hours...
  • Page 15: Adjusting The Air Deflectors

    ADJUSTING THE AIR DEFLECTORS Adjustment of the conditioned air in the upward and downward directions. The horizontal air deflector is automatically set to the proper angle suitable for each operation. The deflector can be swung up and down continuously and also set to the desired angle using the “ (AUTO SWING)”...
  • Page 16: Circuit Breaker

    HOW TO CHANGE THE BATTERIES IN THE REMOTE CONTROLLER Remove the cover as shown in the figure and remove the old batteries. Install the new batteries. Push and pull to The direction of the batteries should match the marks in the direction of arrow mark M.
  • Page 17: Maintenance

    MAINTENANCE WARNING • Before cleaning, stop unit operation with the remote controller and turn off the circuit breaker. CAUTION • Do not expose the unit to water as it may cause an electric shock. • For cleaning inside the air conditioner, consult your sales agent. •...
  • Page 18: Cleaning Of Front Panel

    2. HOW TO INSTALL AND REMOVE THE FRONT PANEL • Be sure to use both hands to grasp the front panel when removing it or attaching it. • The front panel may be installed up or down to suit user preference. Removing 1 Press the hook found at the tip of the resin band 2 Pull the front panel down toward you and once...
  • Page 19: Optional Parts

    OPTIONAL PARTS 1. AIR CLEANSING AND DEODORIZING FILTERS (SPX-CFH5) • The air cleansing and deodorizing filters can absorb even minute dust particles. The filter’s antibacterial function prevents growth of microorganisms Air cleansing and deodorizing filters in the filter. The air cleansing and deodorizing filters also add air purification to the unit’s normal operation to offer a clean and comfortable environment.
  • Page 20 INFORMATION CAPABILITIES Heating Capability • This room air conditioner utilizes a heat pump system that absorbs CAUTION exterior heat and brings it into a room to be heated. As the ambient Do not use a stove temperature gets lower, heating capability will also lower. In such a or any other high- situation, the PAM and inverter work to increase compressor rpm to keep temperature devices...
  • Page 21: Regular Inspection

    REGULAR INSPECTION PLEASE CHECK THE FOLLOWING POINTS EVERY EITHER HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT SHOULD YOU NEED ANY HELP. Check to see if the unit’s earth line has been connected correctly. If the earth line is disconnected or faulty, unit failure or electric WARNING shock hazard may result.
  • Page 22 Steam emitted from the outdoor unit Water generated during defrosting operation evaporates and steam is emitted. Caused as the smells and particles of smoke, food, cosmetics, etc. present in room Odors air become attached the unit and blown off into the room again. Defrosting is underway (as the heating operation is stopped, the microcomputer The outdoor unit continues to operate checks frost accumulated in the indoor unit and instructs the unit to perform...

This manual is also suitable for:

Raf-50nh5Raf-25nh4Raf-50nh4Raf-25nh5

Table of Contents