Maintenance contract
To ensure a reliable operation of the appli-
ance maintenance contracts can be con-
cluded with the competent Kärcher sales
office.
Frost protection
In case of danger of frost:
Empty the fresh and waste water tank.
Store the appliance in a frost-protected
room.
Battery control
Fault indi-
display
cation
–
blinks rapid-
ly
–
blinks slow-
ly
–
glows
blinks red fast
blinks rapid-
ly
slowly blinks red blinks slow-
ly
Risk of injury. Turn the program selection
switch to "OFF" and disconnect the mains
plug before performing any works on the
appliance.
Place the appliance on a stable, even sur-
face and disconnect the battery.
Drain and dispose of the dirt water and
In case of faults that cannot be remedied
using the table below please contact the
customer service.
Faults with display
Fault
Excess temperature
in brush drive
Cable routing fault,
interruption
Failure in the elec-
tronics
Battery defective
Overload on brush
motor
– 11
EN
Faults
DANGER
the residual fresh water.
Remedy
Set the program selection switch to
OFF and let the machine cool down.
Set program switch to OFF. Then se-
lect again the cleaning program. If the
fault recurs, call customer service.
Set program switch to OFF. Check
whether foreign matters are blocking
the brushes, remove foreign matter if
required Then select again the clean-
ing program. If the fault recurs, call
customer service.
27