pulse welding
To use the pulse welding feature, press the PULSE button so that the ON
indicator is lit. Specify the desired welding current average (A) and pulse
time (s). The machine will set the remaining pulse values automatically.
For small welding current values, the chronological pulse ratio is 35% and
the pause current's share of the pulse current is 35 %. The percentages are
slightly altered if the welding current average rises above 145 A.
3.
setup features
Configuring additional features
The machine has additional features that can be selected and adjusted with
the SETUP feature. To activate and deactivate it, press both arrow buttons (3)
simultaneously for at least 5 seconds.
In the SETUP mode, the display will show the name of the parameter to be
adjusted and its numerical value. Select the parameter to be adjusted with
the arrow buttons and change the parameter value with the control knob.
The following parameters and values are available:
Name
displayed
A
b
C
d
E
F
h
J
L
o
S
© Kemppi Oy / 1339
Parameter
Factory
values
setting
1/0
0
1/0
1
1/0
0
1/0
1
5% ... 40%
20%
1/0
0
0.0...2.0 s
0
0,0...10,0 s
1.0 s
5.0...20.0 s
10.0 s
15...99 s
30 s
-3...5
0
Description
End current level selection, 1=I min / 0 =15%
Open-circuit voltage selection,
1 = 30 V (VRD) / 0 = 95 V
Forced stop during downslope
with a brief pressing of the switch,
1 = On / 0 = Off
Alternative switch logic of the MLP panel,
1 = Minilog / 0 = 4T-LOG
Start current level selection
(% of the welding current)
Restore factory settings *),
1 = Restore / 0 = No restore
Minimum setting for pre-gas time
Minumum setting for post-gas time
Maximum setting for pre-gas time
Maximum setting for post-gas time
Arc dynamics (Arc Force)
EN