Kemppi MinarcTig 180 Operating Instructions Manual
Kemppi MinarcTig 180 Operating Instructions Manual

Kemppi MinarcTig 180 Operating Instructions Manual

Hide thumbs Also See for MinarcTig 180:

Advertisement

Käyttöohje • Suomi
1910190
Bruksanvisning • Svenska
0615
Bruksanvisning • Norsk
Bruksanvisning • Dansk
Operation instructions • English
Gebrauchsanweisung • Deutsch
Gebruiksaanwijzing • Nederlands
Manuel d'utilisation • Français
Manual de instrucciones • Español
Инструкции по эксплуатации • По-русски
MinarcTig™ 180

Advertisement

Table of Contents
loading

Summary of Contents for Kemppi MinarcTig 180

  • Page 1 Käyttöohje • Suomi 1910190 Bruksanvisning • Svenska 0615 Bruksanvisning • Norsk Bruksanvisning • Dansk Operation instructions • English Gebrauchsanweisung • Deutsch Gebruiksaanwijzing • Nederlands Manuel d’utilisation • Français Manual de instrucciones • Español Инструкции по эксплуатации • По-русски MinarcTig™ 180...
  • Page 2: Operation Instructions

    MinarcTig OPERATION INSTRUCTIONS ENGLISH © Kemppi Oy 0615...
  • Page 3: Table Of Contents

    3.5.2. MMA welding settings ..............11 3.5.3. TIG welding function ..............11 4. SERVICE ...................12 4.1. Daily maintenance ................12 4.2. Machine disposal ................13 4.3. Ordering numbers ................13 5. TROUBLESHOOTING ..............14 6. TECHNICAL DATA ................15 7. TERMS OF GUARANTEE ..............16 © Kemppi Oy 0615...
  • Page 4: Introduction

    MinarcTig 1. INTRODUCTION Congratulations on purchasing the Kemppi MinarcTig 180 TIG/MMA machine. MinarcTig 180 is designed as a professional welding tool, and with correct use and maintenance, the robust design will provide reliable service throughout its life. Please read this operation manual completely before using the machine! Protective safety equipment must be used at all times when using this equipment! 1.1.
  • Page 5: Safety Instructions

    Never store the machine hanging it from the shoulder strap. The strap is for transporting the machine easily between welding sites, when it is disconnected from the mains power supply. Do not keep the machine near or on hot objects, as the plastic case may melt and damage. © Kemppi Oy 0615...
  • Page 6: Fire Safety

    2.6. Welding fumes Ensure adequate ventilation in the work area. If possible, wear a good quality filtered welding mask or fresh air supplied mask. Take extra special precautions when welding metals containing lead, cadmium, zinc, mercury or beryllium. © Kemppi Oy 0615...
  • Page 7: Machine Use

    The recommended operating temperature range is -20 to +40 degrees Celsius. Site the machine so it does not come into contact with hot surfaces and welding spatter. Make sure the air flow to and from the machine is unrestricted. © Kemppi Oy 0615...
  • Page 8: General View Of The Machine

    50 m. The machine can also be used with a generator. The minimum power for the generator is 3.5 kVA, and the recommended power is 7.0 kVA in order for the machine to operate at maximum capacity. © Kemppi Oy 0615...
  • Page 9 The other end of the gas supply hose should be connected to the outlet of the regulator. UNDER ANY CIRCUMSTANCES, DO NOT CONNECT THE HOSE DIRECTLY TO THE CYLINDER VALVE. ALWAYS USE A REGULATOR AND FLOW METER FOR SAFE AND ACCURATE OPERATION. © Kemppi Oy 0615...
  • Page 10: Welding Power Selection And Electrodes

    MMA welding electrodes MMA welding electrodes must be used with the correct welding polarity (Normally the electrode holder is connected to the positive socket, earth return in the negative socket) © Kemppi Oy 0615...
  • Page 11: Function Controls And Indicator Lights

    2. Pre/Post gas, slope up/slope down and main current parameter indicator lamps. 3. Welding parameter selector arrow keys for items 2. 4. Welding process selection button for MMA or TIG. 5. 2T or 4T TIG torch switch selection button. Select 2T – short welds. 4T – long welds. 6. High frequency ignition selection button. 7. Panel control, TIG Torch remote or foot pedal remote – current control selection button. 8. Parameter adjustment and control encoder potentiometer. © Kemppi Oy 0615...
  • Page 12: Welding Current Regulation And Remote Control

    When ready to end the welding cycle, press and release the torch switch again. The welding current starts to drop (if slope down time is established) until the arc is extinguished and the post © Kemppi Oy 0615...
  • Page 13: Service

    We recommend that you schedule a service inspection of your welding machine every six months if used regularly. An authorised Kemppi service agent will inspect and clean your machine, ensuring that all power connections are tight and secure. Power connections can become loose and oxidised with frequent and high changes in temperature.
  • Page 14: Machine Disposal

    TTC 220, 4 m 627022004 TTC 220, 8 m 627022008 Accessories TIG welding torch controls RTC 10 6185477 RTC 20 6185478 Gas flow gauge AR/clock 6265136 Shielding gas hose (4.5 m) W001077 Shoulder strap 9592162 Remote controls R 10 6185409 R11F 6185407 © Kemppi Oy 0615...
  • Page 15: Troubleshooting

    • Machine’s volume-capacity ratio has been exceeded; wait for the indicator light to switch off • The supply voltage is too low or too high If the machine’s malfunction can not be corrected with these measures, contact the KEMPPI maintenance service. © Kemppi Oy 0615...
  • Page 16: Technical Data

    Striking voltage 10 kV Stick electrodes Ø 1,5–3,25 mm External dimensios 400 x 180 x 340 (L×W×H) Weight 7,8 kg (8,4 kg with supply cabel) Temperature class H (B) Degree of protection IP23C Operating temperature -20 °C...+40°C range Storage temperature range -40 °C...+60°C Recommended generator > 7 kVA © Kemppi Oy 0615...
  • Page 17: Terms Of Guarantee

    MinarcTig 7. TERMS OF GUARANTEE Kemppi Oy provides a guarantee for products manufactured and sold by them if defects in manufacture and materials occur. Guarantee repairs must be carried out only by an Authorised Kemppi Service Agent. Packing, freight and insurance costs to be paid by orderer.
  • Page 18: Kemppi Oy

    Telefax (03) 899 428 Telefax 44 941 536 Telefax (06033) 72 528 www.kemppi.com e-mail: sales.dk@kemppi.com e-mail: sales.de@kemppi.com KEMPPI BENELUX B.V. KEMPPI SP. z o.o. KEMPPIKONEET OY Postbus 5603 UI. Piłsudskiego 2 PL 13 NL – 4801 EA BREDA 05-091 ZABKI FIN –...

Table of Contents