Setup Features - Kemppi MinarcTig Evo 200 Operating Manual

Hide thumbs Also See for MinarcTig Evo 200:
Table of Contents

Advertisement

4.

SETUP FEATURES

Configuring additional features
The machine has additional features that can be selected and adjusted with the SETUP
feature. To activate and deactivate it, press both arrow buttons (3) simultaneously for at least 5
seconds.
In the SETUP mode, the display will show the name of the parameter to be adjusted and its
numerical value. Select the parameter to be adjusted with the arrow buttons and change the
parameter value with the control knob. The following parameters and values are available:
Name
Parameter
displayed
values
A
1/0
b
1/0
C
1/0
d
0...4
E
5% ... 40%
F
1/0
h
0.0...2.0 s
J
0...10 s
L
5...20 s
o
15...99 s
S
-3...5
t
-9...0
*) Factory setting is 1 or 0 depending on the country where the product is sold. Restoring factory settings does not change
the value of this parameter.
**) Happens when exiting SETUP mode and value is 1.
© Kemppi Oy / 1201
Factory
Description
setting
0
End current level selection, 1=I min / 0 =15%
1/0*)
Open-circuit voltage selection: 0 = 95 V, 1 = VRD 30 V / AU VRD 12 V
0
Forced stop during downslope with a brief pressing of the switch,
1 = On / 0 = Off
1
0 = 4T-LOG, 1 = Minilog, 2 = 4T-LOG + Minilog,
3 = Minilog + Search arc, 4 = 4T-LOG_4
20%
Start current level selection (% of the welding current)
0
Restore factory settings **), 1 = Restore / 0 = No restore
0
Minimum setting for pre-gas time
1 s
Minumum setting for post-gas time
10 s
Maximum setting for pre-gas time
30 s
Maximum setting for post-gas time
0
Arc dynamics (Arc Force)
0
Electrode ignition pulse (-9 = No pulse / 0 = Max pulse)
EN
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents