Operation And Fitting Instructions; Operating Conditions; Electrical Installation; Electric Installation For: Okce 100 S/2.2 Kw; Okce 125 S/2.2 Kw - Drazice OKCE 100 S/2,2 kW Operating And Installation Manual

Stationary electrical water heaters
Hide thumbs Also See for OKCE 100 S/2,2 kW:
Table of Contents

Advertisement

2 OPERATION AND FITTING INSTRUCTIONS

2.1 OPERATING CONDITIONS

The tank shall only be used in accordance with the conditions specified on the power plate
and in instructions for electric wiring. Besides legally acknowledged national regulations and
standards, also conditions for connection defined in local electric and water works have to
be adhered to, as well as the installation and operation manual.
The temperature at the place of heater installation must be higher than +2°C; and the room
must not freeze. The appliance has to be mounted at a convenient place; it means that the
appliance must be easily available for potential necessary maintenance, repair or
replacement, as the case may be.
If water is strongly calcareous we recommend that any of the common decalcifying devices
was installed with the appliance, or that the thermostat was set to the minimum operating
temperature of 55
water of adequate quality shall be used. To avoid potential sediments we recommend that
the device was installed together with a water filter.

2.2 ELECTRICAL INSTALLATION

2.2.1 ELECTRIC INSTALLATION FOR: OKCE 100 S/2.2 KW; OKCE 125 S/2.2 KW;

Perform the connection according to the scheme. Factory connection must not be changed! (Obrázek 8). In
the electric wiring casing remove the partition corresponding with the input wire diameter of φ8 or φ10
(Figure 7). The degree of protection of electric parts of the heater is IP 44. Power input of electric element
is 2,200 W.
Figure 7
Connection, repairs, and wiring inspections may only be implemented by a company (person) authorised to
such activity.
Expert connection must be confirmed on the warranty certificate.
o
C (setting to position "ECO") - Figure 19.For proper operation, drinkable
- 12 -