Read carefully the below instructions prior to the installation of the heater! Data sheet pursuant to Directive No 442/2004 Coll. and Annex No 7 Electricity Time of consumption Energy Heat losses Nominal content for heating of Heat losses Heater types efficiency ((Wh/24hr)/l) capacity (l)
4. TECHNICAL PARAMETERS OKCE 160S/2,2 kW OKCE 200S/2,2 kW OKCE 250S/2,2 kW OKCE 100S/2,2 kW OKCE 125S/2,2 kW OKCE 160S/3-6 kW OKCE 200S/3-6 kW OKCE 250S/3-6 kW Capacity Weight 58/67 72/81 80/89 Operating pressure of accumulator MPa Max temperature of HSW °C Heating time from 10 to 60°C 4,5 / 3,2-1,6...
Page 7
The degree of protection of electric parts of the heater is IP 44. Respect rules of protection against electrical injuries in accordance with ČSN 33 2000-4-41. Heating unit - flanges OKCE 100 S/2.2 kW; OKCE 125 S/2.2 kW; OKCE 300 S/1 MPa OKCE 160 S/2.2 kW; OKCE 200 S/2.2 kW;...
Page 8
Mounting 8 x M10 Mounting 12 x M12 OKCE 160 S/3-6 kW; OKCE 200 S/3-6 kW; OKCE 250 S/3-6 kW; OKCE 300 S/1 MPa; TPK 210-12/3-6 kW OKCE 300 S/1 MPa TPK 210-12/5-9 kW TPK 210-12/8-12 kW Mounting 12 x M12 Wiring scheme Notice: Factory connection must not be changed! Cover of wiring with control...
Page 9
6 kW 3 PE - N AC 400 V / 50 Hz OKCE 300 S/1 MPa TPK 210-12/5-9 kW TPK 210-12/8-12 kW TPK 5-9 kW R ~ 1 kW TPK 8-12 kW R ~ 1.33 kW TPK 5-9 kW 5 kW 3 PE - N AC 400 V / 50 Hz 7 kW 3 PE - N AC 400 V / 50 Hz...
Temperature setting Teplota vody se nastavuje otočením knoflíku termostatu. Požadovaný symbol se nastaví proti pevnému bodu na ovládacím panelu. Lower temperature range Upper temperature range limit (about 5°C) limit (about 74°C) Fixed point on the control panel Anti-freezing temperature ”Ideal” temperature (about (about 8°C) 60°C) Notice: Adjusting the thermostat selector to the left backstop does not mean permanent shutoff of the heating...
draining through the safety valve outlet pipe. In common operation, such a check needs to be implemented at least once a month, and after each heater shutdown for more than 5 days. Water can drip from the safety valve through the drain pipe;...
9. HEATER CLEANING AND ANODE ROD EXCHANGE Repetitive water heating causes limestone sediment on both the tank walls and chiefly the flange lid. The sedimentation depends on the hardness of water heated, its temperature, and amount of hot water consumed. We recommend checking and cleaning the tank from scale, if necessary, inspection and possible replacement of anode rod, after two years of operation.
13. FURTHER INFORMATION Notice: 300-1000 litre capacity heaters are screwed onto the bottom wooden palette with M12 screws. When the heater is released from the palette and prior to its putting into operation, 3 adjustable legs supplied as the product accessories have to be installed.
15. ASSEMBLY GUIDE FOR ZIP-FASTENER INSULATION (Only concerns heaters with the capacity of 750 and 1,000 litres) Two people are enough to implement the insulation assembly; three people are required for larger boilers; the assembly must be implemented in areas with the temperature of at least 18 If the insulation includes tank bottom insulation, the latter must be mounted first.