VBI Menu
Item
Time Code
SDI Line Number Configures the SDI ANC line output of VITC/LTC
SDI Alt. Line
Number
Source
SDI Output
SDI Alt. Output
AFD
Function
( SDI Output Port 1 and 2 )
Configures the SDI Alternate ANC line output of
VITC/LTC ( SDI Output Port 3 and 4 )
If timecode is carried by a PES stream,
configure the RD-60 Timecode Source to PES
(default). If a PES time code PID is not
available, the RD-60 can extract the time code
from the GOP by configuring Timecode Source
to VIDEO.
Configures the SDI ANC timecode output for
PASS ( preserve timecode type from transport
stream ), only output LTC, only output VITC, or
output both.
Configures the SDI alternate ANC timecode
output for PASS ( preserve timecode type from
transport stream ), only output LTC, only output
VITC, or output both.
SDI pair
AUDIO2, Route Audio 2 to the selected
SDI pair
AUDIO3, Route Audio 3 to the selected
SDI pair
AUDIO4, Route Audio 4 to the selected
SDI pair
AUDIO5, Route Audio 5 to the selected
SDI pair
AUDIO6, Route Audio 6 to the selected
SDI pair
AUDIO7, Route Audio 7 to the selected
SDI pair
AUDIO8, Route Audio 8 to the selected
SDI pair
Options
0 - Disabled
7 - 22
0 - Disabled
7 - 22
PES
VIDEO
PASS
LTC
VITC
BOTH
PASS
LTC
VITC
BOTH