Check Points Of Every 50 Hours - Kubota WG1605-G-E3 Workshop Manual

Gasoline,lpg natural gas engine
Hide thumbs Also See for WG1605-G-E3:
Table of Contents

Advertisement

WG1605-G-E3,WG1605-L-E3,WG1605-GL-E3, WSM

[3] CHECK POINTS OF EVERY 50 HOURS

CAUTION
• Stop the engine when trying the check and replace prescribed below.
• Make sure to check the fuel line periodically. The fuel line is subject to wear and aging, fuel may leak out
onto the running engine, causing a fire.
Checking Gasoline Fuel Hose and Clamp Bands
Check the fuel hoses every 50 hours of operation.
1. Use good engineering judgment to ensure that all fuel-line
fittings will remain securely connected to prevent fuel leakage
throughout the useful life of the equipment.
Replace the fuel hose together with the clamp every year.
2. If the fuel hose and clamp are found to be damaged or
deteriorate earlier than year, then replace or remedy.
3. After the fuel hose and the clamp have been replaced, make
sure that there is no fuel leakage.
(1) Clamp
Checking LPG / Natural Gas Fuel Hose and Clamp Bands
(WG1605-L-E3, WG1605-N-E3, WG1605-GL-E3, WG1605-LN-E3,
WG1605-GLN-E3)
IMPORTANT
• Never test for gas leaks with a FLAME.
NOTE
• Check for fuel leakage with soapy water or gas-detector, if
leakage is found, correct leakage or replace the hose.
G-12
GENERAL
9Y1210318GEG0020US0
(2) Fuel Hose
9Y1210661GEG0043US0
9Y1210661GEG0014US0
KiSC issued 05, 2014 A