WG1605-G-E3,WG1605-L-E3,WG1605-GL-E3, WSM
Replacing Battery
CAUTION
• When the battery is being activated, hydrogen and oxygen
gases in the battery are extremely explosive. Keep open
sparks and flames away from the battery at all times,
especially when charging the battery.
• When charging battery, remove battery vent plugs.
• When disconnecting the cable from the battery, start with
the negative terminal first. When connecting the cable to
the battery, start with the positive terminal first.
• Never check battery charge by placing a metal object
across the posts.
1. Disconnect the negative terminal and positive terminal.
2. Remove the battery holder.
3. Remove the used battery.
4. Replace the new battery.
5. Tighten the battery holder.
6. Connect the positive terminal.
7. Connect the negative terminal.
G-24
GENERAL
9Y1210318GEG0058US0
KiSC issued 05, 2014 A