Kubota WG1605-G-E3 Workshop Manual page 33

Gasoline,lpg natural gas engine
Hide thumbs Also See for WG1605-G-E3:
Table of Contents

Advertisement

WG1605-G-E3,WG1605-L-E3,WG1605-GL-E3, WSM
Checking Air Cleaner Element (If necessary)
1. Remove the dust cup in the air cleaner.
2. Check the dust in the dust cup and the element.
(When reassembling)
• Install the air cleaner dust cup with "TOP" indicated on the rear
of the cup.
(1) Element
(2) Dust Cap
Cleaning Air Cleaner Element (If necessary)
1. Remove the air cleaner element.
2. Use clean dry compressed air on the inside of the element.
Pressure of compressed air must be under 205 kPa
2
(2.1 kgf/cm
, 30 psi).
Keep reasonable distance between the nozzle and the filter
NOTE
• The air cleaner uses a dry element. Never apply oil to it.
• Do not run the engine with filter element removed.
• Change the element once a year or every 6th cleaning
Checking LPG / Natural Gas Tank Setting Condition (If
necessary) (WG1605-L-E3, WG1605-GL-E3)
1. Check the setting condition of LPG / natural gas fuel tank.
Checking LPG / Natural Gas Fuel Connector
(WG1605-L-E3, WG1605-GL-E3)
1. Check the connector of LPG / natural gas line (hoses and
clamps).
G-10
GENERAL
(3)
"TOP" Mark
9Y1210571GEG0038US0
9Y1210661GEG0050US0
9Y1210661GEG0010US0
9Y1210661GEG0011US0