Gas Adjustment (Conversion To Lpg) - Venini VCG60S Manual

Table of Contents

Advertisement

Gas adjustment (Conversion to LPG)

All work must be carried out by a registered gas
fitter.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
Kind of gas
Natural
L.P.G.
Butane
Propane
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.
o Remove the pan-stands, burners and
flame spreaders (A).
o Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table on next page).
GENERAL INJECTORS TABLE
Nozzle
mm/100
120/55/120
155
118
Semi-rapid
89
70/41/70
92
70
Semi-rapid
54
Burners
Power (MJ/h)
Max.
Wok
12.6
Rapid
10.8
6.3
Auxiliary
3.6
Wok
12.6
Rapid
10.8
6.3
Auxiliary
3.6
Min.
6.3
5.4
3.24
1.8
6.3
5.4
3.24
1.8
20