ADJUSTING THE BURNER MINIMUM FLAME HEIGHT:
NOTE: This adjustment can only be performed by the installer or an authorised service personnel.
The minimum burner flame is factory adjusted for the gas type stated on the gas type label adjacent to the gas
connection and should not require adjustment. Adjustment may be required if the hotplate has been converted
from Natural gas to Universal LPG or vice versa.

GAS CONVERSION INSTRUCTIONS:

The manufacturers servicing instructions detail how authorised personnel may convert the hotplate from Natural
gas to Universal LPG or from Universal LPG to Natural gas. Contact the manufacturer or agent as required.
ADJUSTED FOR NATURAL GAS 1.0kPa
NOZZLES
mm
DIAMETER
WOK
1.70
Rapid
1.40
SEMI RAPID
1.10
AUXILIARY
0.90
Replacement of the nozzles must be performed
by a qualified person. Once the nozzles have
been replaced this label must to be affixed to the
name plate of the appliances.
Natural Gas regulator is to be fitted and adjusted

Start Using Your Appliance

Description
Zone indicators
Flame power
Gas consumption,
MJ/h
13.0
9.5
6.0
4.5
Explanation
These show which zone is under control.
Flame power of the zones,
is the highest.
ADJUSTED FOR ULPG 2.75KPa
NOZZLES
mm
DIAMETER
WOK
0.98
Rapid
0.90
SEMI RAPID
0.77
AUXILIARY
0.55
Replacement of the nozzles must be performed
by a qualified person. Once the nozzles have
been replaced this label must to be affixed to the
name plate of the appliances.
Change the NG regulator to LPG by a qualified
person.
is the lowest and
Gas consumption,
MJ/h
13.0
10.0
6.75
4.0
9