Minimum flow adjustment for hob gas taps.

All work must be carried out by a registered gas
fitter.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o Unscrew the adjusting screw, in order to increase the gas flow or
tighten the adjusting screw to decrease the gas flow.
o The correct adjustment is obtained when the flame has a length of
about 3 – 4 mm.
o For butane/propane gas, the adjusting screw must be tightly
screwed in.
o Refit the control knob.
o Make sure that the flame does not go out by quickly turning from
maximum flow to minimum flow. If it does then remove the control
knob and make further adjustments to the gas flow, testing it again
once the adjustment has been made.
o Repeat this process for each one of the gas taps.
o When converting from Natural Gas to Propane ensure that the NG
regulator is removed and replaced with the Test Point Assembly. A
gas regulator suitable for a supply pressure of 2.75kPa should be
part of the gas tank supply. Replace the old data plate with one,
which is suitable for the type of gas for which the appliance has
been regulated.
IMPORTANT: WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR IN
CARAVANS, IT SHALL NOT BE USED AS A SPACE HEATER
o Switch the burner on
and set the knob at the
minimum position.
o Remove the knob from
the tap and place a
small bladed
screwdriver in the
centre of the tap shaft.
21