Remote Amperage Control (Optional); Weld Control/Arc Condition Information Label - Miller Big Blue 500X CE Owner's Manual

Table of Contents

Advertisement

6-3. Remote Amperage Control (Optional)

Example: Combination Remote Amperage Control (Stick)
Set Switches

6-4. Weld Control/Arc Condition Information Label

.
Complete Parts List available at www.MillerWelds.com
1
Set Range
1
Connect optional remote control to
RC13 (see Section 5-9).
Range = 110 to 225 A DC
Percentage Of Range = 50%
Max = About 168 A DC (50% of 110 to 225)
Max (168 A DC)
Set Control
.
Set weld controls as shown to
achieve softer or stiffer arc condi-
tions for different applications.
Remote Amperage Adjust
Receptacle RC13
In Example:
Min (90 A DC)
Adjust Optional Remote Control
Ref. 154 862-A / Ref. 181 711-A / 803 602
212 944-B
OM-271 838 Page 31