LAMBORGHINI Vela XN 24 MB/IT Installation And Maintenance Manual

LAMBORGHINI Vela XN 24 MB/IT Installation And Maintenance Manual

Advertisement

CALDAIA MURALE A GAS CON BOLLITORE AD ACCUMULO - ALTO RENDIMENTO - MODULANT
EWALL-HUNG GAS BOILER WITH HOT WATER STORAGE TANK - HIGH EFFICIENCY - MODULATING UNIT
CALDERA MURAL A GAS CON ACUMULADOR - ALTO RENDIMIENTO - MODULANTE
CALDEIRA DE PAREDE A GÁS COM TERMOACUMULADOR - ALTO RENDIMENTO - MODULANTE
MANUALE DI
INSTALLAZIONE E
MANUTENZIONE
INSTALLATION
AND MAINTENANCE
MANUAL
O N
I C
" M
A S
E G
T O
T E N
P R
E R
N S
. U
L ' I
S I G
A K
A L
A N
E M
E M
A S
P L E
U S
O V
E "
E D
T H
N D
L A
H A
A R
N
G A
E G
" M
T E N
T R
E N
T O
L L E
D E
R E
F O
N T
E L
R E
L D
V O
N T
U A
F A
T E
A N
. U
" M
S R
A O
N
MANUAL PARA
LA INSTALACIÓN Y EL
MANTENIMIENTO
"
S O
E
A R
D ' U
G N
L E
S E
U A
A N
T
T E
H A
E T
U R
R
I S
S E
E S
L "
E U
U A
T H
T O
A D
E R
R I O
I L I D
"
U A
S O
A B
U S
E U
A M
A L
L D
L E
U A
A N
R O
G A
"
S O
E U
E
24 MB/IT
MANUAL DE
INSTALAÇÃO E
MANUTENÇÃO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vela XN 24 MB/IT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LAMBORGHINI Vela XN 24 MB/IT

  • Page 1 " D ' U " M T E N L ' I L ” S I G R I O I L I D P L E ” E “ “ M T E N L L E ” “ M CALDAIA MURALE A GAS CON BOLLITORE AD ACCUMULO - ALTO RENDIMENTO - MODULANT EWALL-HUNG GAS BOILER WITH HOT WATER STORAGE TANK - HIGH EFFICIENCY - MODULATING UNIT CALDERA MURAL A GAS CON ACUMULADOR - ALTO RENDIMIENTO - MODULANTE...
  • Page 2 ENGLISH Read carefully all warnings and instructions contained in this manual as they give important instructions regarding safety, installation and maintenance. Keep this manual for future reference. Installation must be carried out by qualified personnel who will be responsible for respecting existing safety regulations.
  • Page 3: Table Of Contents

    1959 with a widespread network of agents and concessionary agents to constantly guarantee the presence of our product on the market. Alongside this is the support of a technical service, “LAMBORGHINI SERVICE”, which is entrusted with the qualified servicing of the product.
  • Page 4: General Instructions

    BY AUTHORISED SKILLED TECHNICIANS. TO ENSURE THAT BOILER IS INSTALLED CORRECTLY AND THAT IT FUNCTIONS PROPERLY, WE RECOMMEND THAT ONLY LAMBORGHINI ACCESSORIES AND SPARE PARTS BE USED. ON NOTICING THE SMELL OF GAS DO NOT TOUCH ANY ELECTRIC SWITCH. OPEN DOORS AND WINDOWS.
  • Page 5: Description

    If the FLUE CONTROL device is changed make sure you observe assembly and probe positioning instructions carefully and use only original LAMBORGHINI spare parts. If there is a fume evacuation anomaly act quickly to prevent the formation of Carbon Monoxide, a...
  • Page 6: Main Components

    MAIN COMPONENTS LEGEND Hot water expansion tank 10 Safety flow-switch 16 Stainless steel water-heater 11 Modulating coil Water-heater sensor 17 Thermohydrometer Heating expansion tank 12 Gas valve 18 Malfunction warning light Flue control 13 Hot water circuit: 19 ON/OFF warning light - 8-bar safety valve Delivery sensor 20 Lock-out warning light...
  • Page 7: Dimensions

    DIMENSIONS mm TECHNICAL FEATURES Thermal capacity Min. thermal Hot water supply Operating Expansion Weight capacity pressure tank MODELL Heating Peak output Water Supply Input Output Input Output Heating circuit water in first 10 heater 30 °C ∆ water circuit minutes max.
  • Page 8: Gas - Nozzle Calibration

    GAS - NOZZLE CALIBRATION The boilers leave the factory calibrated and ready to operate with NATURAL GAS and LIQUID GAS. For proper calibration, see the table below: Jets pressure mbar Delivery Burner jets Gas type L.C.V. VELA X N 24 VELA X N 24 VELA X N 24 Ø...
  • Page 9: Electrical Connections - Wiring Diagrams

    The power lead must only be replaced by another with the following characteristics: “HAR H05 vv-F” 3 x 1.00 mm . (You are strongly advised to use original LAMBORGHINI accessories and spare parts only). Installation must be made in compliance with safety REGULATIONS IN FORCE.
  • Page 10 ASSEMBLY DIAGRAM Timer Rmax Jumper to be cut if limit thermostat is required Panel connection ON/OFF Malfunction Lock-out warning light warning light warning light CONTROL PANEL LEGEND temperatures Modulating coil Slow ignition adjustment Heating potentiometer Heating circulator Rmax. Heating max. power adjustment Selector: Off Ignition electrode Delivery sensor...
  • Page 11: Malfunctions And Adjustments

    MULFUNCTIONS AND ADJUSTMENTS Constant light: No water circulation or modulating Constant light: Ignition coil shutdown Fast flashing light: Fast flashing light: TST Sensor fault shutdown Slowly flashing light: Flue control Should the boiler shut down it must be reset by rotating function selector to the reset position A. Legend: GPL - METHANE...
  • Page 12: Water Connection

    WATER CONNECTION Fit the supporting hooks and attach the assembly template, moving it up to the wall; fit all the pipes, starting with the end pipe fittings already mounted on the template: system supply, system return, cold water, hot water, any gas pipes and electric mains leads with room thermostat. Once the pipes have been fitted, the end pipe fittings can be removed and ordinary caps fitted, ready for hydraulic tests to be carried out.
  • Page 13: Water Circuit

    WATER CIRCUIT 10 11 LEGEND Hot water outlet Cold water inlet Burner Heating expansion tank System return Automatic air bleed valve System delivery Circulator Magnesium anode Heating safety valve Water-heater sensor Pressostato differenziale aqua Stainless steel water-heater Filling tap Ignition electrode Electric 3-way valve Detection electrode Modulating coil...
  • Page 14: Installation

    INSTALLATION To be carried out by qualified personnel. The installation must be in compliance with the stipulations of the law regarding the evacuation of combustion materials according to the REGULATIONS IN FORCE. The gas fume evacuation must be effected with a pipe of a diameter not less than that required by the boiler and it must be connected to a flue pipe suitable for the capacity of the installation.
  • Page 15: Flue Exhaust Connection

    If the Flue Control device is changed use only original spare parts. If the device trips repeatedly check for proper fume outflow via the chimney flue and contact a Lamborghini Service Centre. Ø 130 mm *...
  • Page 16: Adjustments

    ADJUSTMENTS The boilers have a fast opening gas valve. The necessary calibration for gas flow-rate may be obtained from a double modulator coil. Calibration of the slow ignition (pre-calibrated in the factory) is electronically done and is adjustable (for optimising and for gas type conversion) by the trimmer RLA on the electronic board.
  • Page 17: Switching Off

    Frequency of inspection depends on the specific conditions of installation and use but it is advisable to have the unit checked once a year by authorised Lamborghini Service personnel. Only properly quali- fied personnel with specific knowledge in the field of safety, efficiency, environmental hygiene and combustion may carry out work on the unit.
  • Page 18: Knob Assembly Instructions

    checking general external appearance of boiler checking for proper ignition, shutdown and operation of both hot water and heating functions checking for proper seal on gas/water fittings and pipes. checking gas consumption at minimum and maximum power checking position of ignition electrode checking position of detection electrode checking combustion and efficiency parameters checking the no-gas safety device...
  • Page 19 Then remove the knobs from the front panel. Screw the display board onto the back of the panel and insert the knobs so that the arrows on the knobs are set at the minimum value (zero). Trimmer Enlarged detail of the cor- rect knob potentiometer housing...
  • Page 20: Operation With Different Types Of Gas

    OPERATION WITH DIFFERENT TYPES OF GAS CONVERSION FROM NATURAL GAS TO LIQUID GAS Replace the burner jets, insert the diaphragm as illustrated in the diagram included with the relevant kit. Shift the jumper JP1 on the modulating board from the NATURAL GAS position to the B-P position. Then adjust properly as described in the “ADJUSTMENT”...
  • Page 21 TRATTAMENTO ACQUA CONDIZIONAMENTO Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più opportuno per l'evoluzione del prodotto. The illustrations and details reported are indicative only and are not binding. LAMBORGHINI reserves the right to introduce alterations and/or amendmentsas it deems fit and proper for the development of the product without the obligation of providing prior notice.
  • Page 22 CALDAIA MURALE A GAS CON BOLLITORE AD ACCUMULO ALTO RENDIMENTO - MODULANTE MANUALE PER L'UTENTE Alla cortese attenzione del sig. INSTALLATORE: Consegnare il presente manuale d'uso all'UTENTE WALL-HUNG GAS BOILER WITH HOT WATER STORAGE TANK - HIGH EFFICIENCY - MODULATING UNIT USER MANUAL For the attention of the INSTALLATION TECHNICIAN: Make sure that this manual is handed over to the USER...
  • Page 23 Read carefully this guide in order to know any detail concerning the product’s operation system. The “LAMBORGHINI SERVICE” after-sales centres are at your disposal to ensure QUALIFIED MAINTENANCE and PROMPT SERVICE.
  • Page 24: General Instructions

    AUTHORISED SKILLED TECHNICIANS. TO ENSURE THAT BOILER IS INSTALLED CORRECTLY AND THAT IT FUNCTIONS PROPERLY, WE RECOMMEND THAT ONLY LAMBORGHINI ACCESSORIES AND SPARE PARTS BE USED. ON NOTICING THE SMELL OF GAS DO NOT TOUCH ANY ELECTRIC SWITCH. OPEN DOORS AND WINDOWS.
  • Page 25: Instructions For The Use

    Call exclusively professionally qualified personnel. Any repair must be carried out by an after-sale service centre “LAMBORGHINI SERVICE” authorised by the manufacturing firm, and using original replacements exclusively. Non-observance of the above could compromise the safety of the appliance.
  • Page 26: Checks And Maintenance

    CHECKS AND MAINTENANCE ● Before starting up the boiler ask qualified personnel “LAMBORGHINI SERVICE” to check: a) that the data on the information plate corresponds to that required by the gas, electrical and water supply networks; b) that the pipes which branch off from the boiler are lined with suitable thermally-insulated sheathing;...
  • Page 27 DIMENSIONS mm. CONTROL PANEL AND MULFUNCTIONS Constant light: No water Constant light: Ignition circulation or modulating coil shutdown Fast flashing light: Sensor Fast flashing light: TST fault shutdown Slowly flashing light: Flue control Should the boiler shut down it must be reset by rotating function selector 6 to the reset position A. Lock-out warning light Hot water adjustment potentiometer ON/OFF warning light...
  • Page 28: Start Up - Operation - Switching Off Instructions

    If combustion fumes re-enter the room they may cause chronic or acute intoxication that can be fatal. If the Flue Control device is changed use only original spare parts. If the device trips repeatedly contact a Lamborghini Service Centre. WARNING: When Summer...
  • Page 29: Fault-Finding Chart

    FAULT-FINDING CHART FAULT CAUSE REMEDY 1 NO IGNITION A.Gas tap closed A. Open gas tap B. Boiler in lock-out mode B. Reset by pressing C. No flame detection C. Call technical service D.No ignition spark D. Call technical service E. Air inside pipes E.
  • Page 30 TRATTAMENTO ACQUA CONDIZIONAMENTO Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più opportuno per l'evoluzione del prodotto. The illustrations and details reported are indicative only and are not binding. LAMBORGHINI reserves the right to introduce alterations and/or amendments as it deems fit and proper for the development of the product without the obligation of providing prior notice.

Table of Contents