  • Page 1 Installation 3 Series Built-In Gas Cooktops...
  • Page 2: Table Of Contents

    Table of Contents Warnings & Important Safety Instructions _______________________________________________3 Dimensions _________________________________________________________________________6 Specifications _______________________________________________________________________7 Cutout Dimensions __________________________________________________________________8 Cutout Dimensions (Cooktop over Single Electric Oven)__________________________________9 Downdraft Dimensions ______________________________________________________________9 Clearance Dimensions (Proximity to Cabinets)__________________________________________10 Clearance Dimensions (Wood/Composite Overlay) _____________________________________11 Electrical & Gas Requirements _______________________________________________________12 General Information ________________________________________________________________14 Installation _________________________________________________________________________15 Gas &...
  • Page 3: Warnings & Important Safety Instructions

    IMPORTANT – Please Read and Follow Your safety and the safety of others is • Before beginning, please read these very important. instructions completely and carefully. We have provided many important safety • DO NOT remove permanently affixed messages in this manual and on your labels, warnings, or plates from product.
  • Page 4 IMPORTANT – Please Read and Follow DANGER WARNING FIRE/EXPLOSION CHEMICAL HAZARD HAZARD If not installed, operated and maintained in accordance IF THE INFORMATION IN with the manufacturer’s THIS MANUAL IS NOT instructions, this product could expose FOLLOWED EXACTLY, A FIRE OR you to substances in fuel or from fuel EXPLOSION MAY RESULT CAUSING combustion which can cause death or...
  • Page 5 IMPORTANT – Please Read and Follow WARNING ELECTRICAL GROUNDING INSTRUCTIONS The cooktop must be electrically grounded in accordance with local codes or, in the absence of codes, with the ANSI/NFPA No. 70-latest edition. Installation should be made by a licensed electrician. This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged...
  • Page 6: Dimensions

    Dimensions 30” Gas Cooktop - 3 / ( 7 8 4 ” ” ( 5 3 36” Gas Cooktop - 3 / ( 9 3 4 ” ” ( 5 3 2-1/2” 4-3/8” (6.4 cm) (11.1 cm) 2-1/2” (6.4 cm) 1-3/4”...
  • Page 7: Specifications

    Specifications Gas Cooktops Description 30” W. Model 36” W. Model Overall width 30-3/4” (78.1 cm) 36-3/4” (93.3 cm) Overall height from bottom 4-3/8” (11.1 cm) to top of grate Overall depth from rear 21” (53.3 cm) Cutout width 29-1/4” (74.3 cm) min. to 35-1/4”...
  • Page 8: Cutout Dimensions

    Cutout Dimensions 30” W. Model 36” W. Model 29-1/4” (74.3 cm) min. to 35-1/4” (89.5 cm) min. to 29-7/8” (75.9 cm) max. 35-7/8” (91.1 cm) max. 20” (50.8 cm) min. to 20-1/4” (51.4 cm) max. 2-1/2” (6.4 cm) min. Note: Based on 24” deep cabinet with 3/4” backsplash. If countertop is less than 1-1/2”...
  • Page 9: Cutout Dimensions (Cooktop Over Single Electric Oven)

    Cutout Dimensions (RVGC/CRVGC Cooktop over Single Electric Oven) ” m ( 9 1 i n . - 1 / ( 7 1 8 ” 30” W. Model - 1 / 29-1/4” (74.3 cm) min. to ( 3 6 4 ” .
  • Page 10: Clearance Dimensions (Proximity To Cabinets)

    Clearance Dimensions (Proximity to Cabinets) Proximity to Side Cabinet Installation Minimum Clearances from Adjacent Combustible Construction • The cooktop may be installed directly to existing base cabinets. • Above countertop 36” (91.4 cm) minimum • The cooktop CANNOT be installed directly •...
  • Page 11: Clearance Dimensions (Wood/Composite Overlay)

    Clearance Dimensions (Wood/Composite Overlay) The bottom of a standard hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. / C o above the countertop. This would typically o s i result in the bottom of the hood being e r l 66”...
  • Page 12: Electrical & Gas Requirements

    Electrical & Gas Requirements Electrical Requirements There is no connection necessary beyond Manual shut-off valve: plugging the unit into a polarized, • The installer-supplied valve must be grounded, 120 volt, 60 Hz, 15 amp circuit. A installed in the gas service line ahead of minimum of 120VAC is required for proper the appliance and regulator in the gas operation of gas ignition systems.
  • Page 13 Electrical & Gas Requirements Rigid Connections: Initial Ignition of Burners • Incoming gas is brought from an intake pipe (not supplied) at the rear of the unit All cooktops are tested before leaving the to the pressure regulator; then to the factory.
  • Page 14: General Information

    General Information Electrical Requirement CAUTION Normal grounded household current, 120 volts, 60 Hz, 15 amps, single phase. BURN HAZARD Electrical installation should comply with national and local codes. The use of cabinets for storage above the appliance may result in a potential burn Air Supply and Ventilation hazard.
  • Page 15: Installation

    Installation Remove the grates and burner caps. Turn the cooktop over and place into countertop opening. Gas & Electrical Connection Note: Refer to “Electrical & Gas Requirements” section for proper installation information.
  • Page 16: Bracket Installation

    Bracket Installation Cooktop Cooktop Countertop Countertop Screw Eye Bolt Bracket Bracket Screw hold down brackets using the #10 x 1/2” sheet Screw the eye bolt into the self-retaining nut and metal screw to the burner box. (2 brackets per side) tighten firmly against bottom of countertop.
  • Page 17: Final Preparation

    Final Preparation • New units are cleaned at the factory • All stainless steel parts should be wiped to remove any visible signs of dirt, oil, regularly with hot, soapy water grease, etc. remaining from the and with a liquid cleanser designed for manufacturing process.
  • Page 18: Service & Registration

    Only authorized replacement parts may be used in performing service on the appliance. All servicing should be referred to a qualified technician. Contact Viking Range, 1-888-845-4641, for the nearest service parts distributor in your area or write to: VIKING RANGE, LLC...