Radion Contact Rm; Installation Considerations - Bosch RFRC-OPT Reference Manual

Hide thumbs Also See for RFRC-OPT:
Table of Contents

Advertisement

RADION receiver OP
10
RADION contact RM
The RFDW-RM is a recessed-mounted wireless transmitter device used for monitoring doors
and windows. Features include:
Power/voltage
Battery replacement
Battery life
Device testing
Dimensions (transmitter)
Dimensions (magnet)
Relative humidity
Temperature (operating)
Frequency
Tab. 10.11: Specifications
10.1
Installation considerations
You have a variety of installation options to consider when installing the device. You must
acknowledge the unique installation approach prior to installation. Some installation
considerations include:
Bosch Security Systems, Inc.
Self-contained transmitter with magnetic reed switch
Tamper protection
Recessed mounting on doors or windows
The installation of this device is suitable for wood surfaces. This device is not suitable for
steel surfaces.
The transmitter housing was designed to be open with a coin. Using a screwdriver may
cause damage to the plastic top.
When reinserting the PCB (battery and antenna assembly), verify that the PCB assembly
fits into the grooves of the transmitter housing.
When reinserting the plastic top, verify that the top fits into the designed grooves of the
transmitter housing.
When installing the transmitter in an overhead location, be mindful that the PCB
assembly may fall out of the transmitter housing.
The removal of the plastic flaps is optional, depending on your installation needs.
For added security, you can use an adhesive with the screws to secure the transmitters
and magnets.
One AAA Lithium battery, 1.5 VDC (
Power source type: C
Low battery level: 0.9V
Energizer L92. Check your battery yearly to ensure proper
functionality.
Up to 5 years
To ensure proper functionality, the device must be tested at
least once every year by an installer.
19.00 mm x 104.80 mm
(0.75 in x 4.12 in)
22 mm x 28 mm x 15 mm
(0.87 in x 1.10 in x 0.59 in)
0% to 93%, non-condensing
Functional range: -10°C to +49°C (+14°F to +120°F)
EN 50130-5 Class II only: -10 C to 40 C (+14 F to +104 F)
433.42 MHz
Reference Guide
RADION contact RM | en
33
)
2014.12 | 02 | F.01U.261.835