For best receiver reception results, place the receiver in a central location among the
transmitters. For optimal communication results in situations where there is a long distance
between the transmitting device and the system receiver, it might be necessary to install
repeaters.
Notice!
Mount the receiver in a location away from metal objects. Metal objects (duct work, wire
mesh screens, boxes) reduce RF range.
3.3.1
RFRC-OPT configuration
RADION Wireless System operates on a radio frequency of 433.42 MHz.
Configuring the address switch
The address switch determines the receiver's numeric address value which the receiver will
use to report receiver status information to the control panel. Set the address to the receiver
prior to installation. Address 1 through 8 are valid address settings for the receiver. Use a
slotted screwdriver to set the address switch.
Address settings
The receiver address switches provide a single-digit setting for the receiver's address. The
receiver uses addresses 1 through 8. Addresses 0 and 9 are invalid and will cause the receiver
to enter into an Option bus communication error state. This will cause the receiver to be
unrecognized by the control panel. Refer to your control panel documentation for information
on the valid addresses for that control panel. The figure below shows the address switch
setting for address 1.
Figure 3.1: Address switch set to 1
Option Bus address settings
Depending on the supporting control panel, use the following table as a reference when
selecting the address setting switch for the compatible control panel.
Address switch setting
1
2
3
4
5
6
7
Bosch Security Systems, Inc.
Function
RADION receiver 1
RADION receiver 2
Legacy Mode receiver 1
Legacy Mode receiver 2
Maintenance Mode, EN50131 Grade 2 (6dB attenuation), for
RADION receiver 1
Maintenance Mode, EN50131 Grade 2 (6dB attenuation), for
RADION receiver 2
Maintenance Mode, EN50131 Grade 2 (6dB attenuation), for
legacy receiver 1
Reference Guide
RADION receiver OP | en
2014.12 | 02 | F.01U.261.835