Operating Temperature; Manual Operation - Vivax ACP-09CH25AEM User Manual

Hide thumbs Also See for ACP-09CH25AEM:
Table of Contents

Advertisement

NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.

Operating temperature

Mode
Temperature
Room temperature
Outdoor temperature
CAUTION:
1. If air conditioner is used outside of the above conditions, certain safety protection
features may come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please sets the vertical
air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.

Manual operation

Manul operation can be used temporarily in case the remote controller is disable or
maintenance necessary.
Panel
Manual control
AUTO/COOL
button
Cooling operation
>17 C
18 C
43 C
~
( -15 C
43 C:For the models with
~
low temperature cooling system)
6
OPERATING INSTRUCTIONS
Heating operation Drying operation
<30 C
-7 C
24 C
~
1
Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
Push the button until the AUTO indicator
2
is lit, the unit will work in forced AUTO
mode (the default setting temperature
is 24 ).
Close the panel firmly to its original
3
position.
CAUTION:
Once you push the manual button, the
operation mode is shifted in an order as:
AUTO, COOL, OFF.
Push the manual button until the POWER
indicator light flashes rapidly (five times
per second), the unit now is operating in
forced COOL mode. This is used for
testing purposes only.
To restore the remote controller operation,
use the remote controller directly.
>10 C
11 C
4 3 C
~