Installation

This chapter gives step-by-step installation instructions for the
DMC-805G.

Selecting a Site for the Equipment

As with any electric device, you should place the equipment where it
will not be subjected to extreme temperatures, humidity, or
electromagnetic interference. Specifically, the site you select should
meet the following requirements:
1.
The ambient temperature should be between 32 and 104 degrees
Fahrenheit (0 to 40 degrees Celsius).
2.
The relative humidity should be less than 90 percent,
non-condensing.
3.
Surrounding
electromagnetic field (RFC) standards for IEC 801-3, Level 2
(3V/M) field strength.
4.
Make sure that the equipment receives adequate ventilation. Do
not block the ventilation holes on each side of the switch or the
fan exhaust port on the side or rear of the equipment.
5.
The power outlet should be within 1.8 meters of the switch.

Sliding Switch

There is a two pin DIP switch on the module which define as switch 1
and switch 2:
Switch 1: Fiber mode switch
When the switch was turned to "On", it means that the fiber was
turned to forced mode, and "Off" for auto-negotiation mode.
Note: Be sure the opposite end is using the same setting (forced or
Auto-negotiation). And when using two converters at the same time, the
two converters MUST set to forced mode.
Switch 2: LLR
When the switch was turned to "On", it means that the LLR was
enabled and "Off" for disabled.
Note: When using two converters, don't enable the both devices' LLR
function at the same time.