Install Filters - Frigidaire PL36WC40EC Manual

Hide thumbs Also See for PL36WC40EC:
Table of Contents

Advertisement

Available languages

Available languages

9. Carefully place the decorative flue on the hood. Fig. 16.
- On ducted installation in rooms with 8-foot ceilings, the air vents are concealed. Install the flue with the air vents
down.
- On non-ducted installations in rooms with 8-foot ceilings, the air vents are exposed. Install the flue with the air
vents up.
- On ducted and non-ducted installations in rooms with 9-foot ceilings, the vents are exposed. Install the flue with
air vents up.
ROOMS WITH 10-FOOT CEILINGS
Rooms with 10-foot ceilings require flue extension model 5304447637, available from your local dealer.
10. Discard the upper flue supplied with the product. Replace it with the flue extension 5304447637.
11.
Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 17.
12.
Secure the flue with (2) 3.9x9.5mm mounting screws. Fig. 17.
UPPER
UPPER FLUE VENTS
FLUE
LOWER
FLUE

INSTALL FILTERS

(DUCTED AND NON-DUCTED HOODS)
1. To remove the GREASE filter, push in on the metal latch tab and tilt filter
downward to remove.
2. To install the GREASE filter, align rear filter tabs with slots in the hood. Depress
the metal latch tab, push filter into position and release. Make sure filter is
securely engaged after installation.
NOTE: Prior to use, remove protective film from the filter frame.
(NON-DUCTED HOODS ONLY)
1. To remove the CHARCOAL filter, push in on the front filter latch. Pull the filter
down to disengage the rear filter tabs.
2. To install the CHARCOAL filter, align the rear filter tabs with slots in the hood.
Push the filter up into place until the front latch snaps securely into the slot.
Make sure the filter is securely engaged after assembly.
3. Install GREASE filter after charcoal filter is installed.
EXPOSED
UPPER
FLUE
LOWER
FLUE
UPPER FLUE VENTS
CONCEALED
FIG.16
- 8 -
3.9x9.5mm
MOUNTING SCREWS
GREASE
FILTERS
TABS
LATCH
NON-DUCTED
RECIRCULATION
FILTER
FIG.17
Fig. 18
Fig. 19

Advertisement

Table of Contents
loading

Table of Contents