Install Range Hood (Ducted Version); Installing Range Hood (Recirculating Version) - Frigidaire FHWC3025 Installation, Use & Care

Hide thumbs Also See for FHWC3025:
Table of Contents

Advertisement

PREPARE THE LOCATION
Style 3 - Cut Openings for 3¼" x 10" (8.3 x 25.4
cm) Rectangular Vent Transition to Round Vent
Roof Venting
To make a circular vent opening on the underside of the
cabinet top:
1.
Mark a centerline on the underside of the top of cabinet.
.
Mark a line 5" (12.7 cm) from the back wall on the
underside of the top of cabinet.
.
Use a compass or a circle template to draw a circle with
a diameter of 7½" (19 cm).
Use saber or keyhole saw to cut the circular vent
opening.
Ø 7½"
(19 cm)
*5"
(12.7 cm)
Style 4 - Cut Openings for " (1.8 cm) Round Vent
to Round Vent Transition
Roof Venting
To make a circular vent opening on the underside of the
cabinet top:
NOTE: The 7" round transition kit, part number
5304487139, is required for this installation.
1.
Mark a centerline on the underside of the top of cabinet.
.
Mark a line 5" (12.7 cm) from the back wall on the
underside of the top of cabinet.
.
Use a compass or a circle template to draw a circle with
a diameter of 7½" (19 cm).
Use saber or keyhole saw to cut the circular vent opening.
4.
Repeat steps 1-3 for the underside of the top of the
cabinet.
*Ø 7½"
(19 cm)
*5"
(12.7 cm)
10
Centerline
Cabinet
cutouts
*From wall, not
cabinet frame
Centerline
*
Cabinet
cutouts
*
*From wall, not
cabinet frame
Install Vent System
1.
Install vent through the vent opening in upper cabinet
or wall. Complete venting system according to the
selected venting method. See "Venting Requirements"
section.
.
Use caulking to seal exterior wall or roof opening
around the cap.
INSTALL RANGE HOOD
(Ducted version)
NOTE
Your model will have a 3¼" x 10" (8.3 x 25.4
cm) rectangular vent connector on the inside of
the range hood.
1.
Unpack the 3¼" x 10" (8.3 x 25.4 cm) rectangular
vent from the inside of your range hood. To detach the
vent connector, remove the 2 installation screws
(.35x .95cm) and keep the screws in a safe place to
reinstall later (see Step 5).
A. 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper
B. 3.5 x 9.5 mm screws
.
Lift the range hood up under cabinet and determine
final location by centering beneath cabinet. Mark on
the underside of cabinet the location of the 4 keyhole
mounting slots on the range hood (See slot dimensions
on page 6). Set range hood aside on a covered surface.
A
A. Keyhole slot
A
B
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fhwc3625

Table of Contents