PREPARE THE LOCATION
Install Vent System
1.
Install vent through the vent opening in upper cabinet
or wall. Complete venting system according to the
selected venting method. See "Venting Requirements"
section.
.
Use caulking to seal exterior wall or roof opening
around the cap.
INSTALL RANGE HOOD
(Ducted version)
1.
Detach the 3¼" x 10" (8.3 x 25.4 cm) rectangular
damper from the package.
A
A. 3¼" x 10" (8.3 x 25.4 cm) rectangular vent damper
For roof installations, remove the top rectangular
•
vent knockout A.
For wall installations, remove the
rear rectangular vent knockout B.
A. Top rectangular knockout
B. Rear rectangular knockout
EN-10
vent
A
B
Vent Damper Installation
Install 3¼" x 10" (8.3 x 25.4 cm) vent damper.
Attach to range hood using the indicated screws
provided in hardware kit.
If a vent damper is installed with a wall cap with
•
damper, check that they do not interfere with each
other. Remove the vent damper flap if
Power Supply Cable Installation
1.
For direct wire installations, run the home power
supply cable according to the National Electric Code
or CSA standards and local codes and ordinances.
NOTE
Do not reconnect power until the installation is
complete.
Before starting the installation, remove the
vent grill and grease filters.
.
Remove the screws from the terminal box cover.
Remove terminal box cover and set aside.
A. Terminal box cover
B. Screw
Install the 3¼" x 10" (8.3 x
25.4 cm) rectangular vent
transition
A. 3¼" x 10" (8.3 x 25.4 cm)
rectangular vent transition
B. 6 - 0.40 x 0.80 cm screws
C. Rectangular vent knockouts
they interfere.
B
A