Display
For purposes of this explanation,
all parts of the display are shown
as lit. During actual operation, only
the relevant items will be lit.
Identifies the current operation
Shows the operating mode, etc.
* Multilanguage display is sup-
ported.
"Centrally Controlled" indicator
Indicates that operation of the re-
mote controller has been prohib-
ited by a master controller.
"Timer Is Off" indicator
Indicates that the timer is off.
Temperature Setting
Shows the target temperature.
Caution
Only the Power on indicator lights when the unit is stopped and power supplied to the unit.
If you press a button for a feature that is not installed at the indoor unit, the remote controller will display the "Not Available"
message.
If you are using the remote controller to drive multiple indoor units, this message will appear only if he feature is not
present at the parent unit.
When power is turned ON for the first time, it is normal that "PLEASE WAIT" is displayed on the room temperature indica-
tion (For max. 2minutes). Please wait until this "PLEASE WAIT" indication disappear then start the operation.
Day-of-Week
Shows the current day of the week.
Time/Timer Display
Shows the current time, unless the simple or Auto Off
timer is set.
If the simple or Auto Off timer is set, shows the time
remaining.
TIME SUN MON TUE WED THU FRI SAT
TIMER
AFTER
ERROR CODE
˚F˚C
ONLY1Hr.
Up/Down Air Direction indica-
tor
The indicator
shows the direc-
tion of the outcoming airflow.
"One Hour Only" indicator
Displayed if the airflow is set to
weak and downward during COOL
or DRY mode. (Operation varies
according to model.)
The indicator goes off after one
hour, at which time the airflow di-
rection also changes.
7
Hr
ON
AFTER
OFF
FUNCTION
˚F˚C
FILTER
WEEKLY
SIMPLE
AUTO OFF
Room Temperature display
Shows the room temperature.
Louver display
Indicates the action of the swing
louver. Does not appear if the
louver is stationary.
(Power On indicator)
Indicates that the power is on.
"Sensor" indication
Displayed when the remote controller
sensor is used.
"Locked" indicator
Indicates that remote controller but-
tons have been locked.
"Clean The Filter" indicator
Comes on when it is time to clean the
filter.
Timer indicators
The indicator comes on if the corre-
sponding timer is set.
Fan Speed indicator
Shows the selected fan speed.
Ventilation indicator
Appears when the unit is running in
Ventilation mode.

Hide quick links: