INDOOR UNIT

PLFY P VFM E

OPERATION MANUAL

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro
della stessa.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a uni-
dade de ar condicionado.
DRIFTSMANUAL
Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug.
DRIFTSMANUAL
Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
PARA O UTILIZADOR
TIL BRUGER
FÖR ANVÄNDAREN

Advertisement

loading

Summary of Contents for Mitsubishi Electric PKFY-P-VKM-E

  • Page 1: Indoor Unit

    INDOOR UNIT PLFY P VFM E OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2 4. Timer..................13 8. Specifications ...............19 Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of- life, should be disposed of separately from your household waste. If a chemical symbol is printed beneath the symbol (Fig. 1), this chemical symbol means that the battery or accumulator contains a heavy metal at a certain concentration.
  • Page 3 PKFY-P·VKM-E PLFY-P·VFM-E PCFY-P·VKM-E Fan speed 2 speed 3 speed + Auto* 4 speed + Auto* Steps 4 steps 5 steps 5 steps Vane Auto Swing Louver Manual Manual Filter Normal Long-life Long-life Filter cleaning indication 100 hr 2,500 hr 2,500 hr * This operation is available only using the remote controller that is able to set its Fan speed setting "Auto".
  • Page 4 Main Main menu Vane·Louver·Vent. (Lossnay) High power Room Timer Cool Set temp. Auto Weekly timer OU silent mode Main display: Cursor Page Mode Temp. Function buttons Press to turn ON/OFF the indoor unit. This lamp lights up in green while the unit is in operation. It blinks while the remote controller is starting up or when there is an error.
  • Page 5 The main display can be displayed in two different modes: “Full” and “Basic”. The factory setting is “Full”. To switch to the “Basic” mode, change the setting on the Main display setting. (Refer to operation manual included with remote controller.) <Full mode>...
  • Page 6 Transmission area Transmission indicator Remote controller display Timer indicator * For explanation purposes, all of the items that appear in the display are shown. * All items are displayed when the Reset button is pressed. Operation areas ON/OFF button Set Temperature buttons Fan Speed button (Changes fan speed) Timer Off button Timer On button...
  • Page 7 Press the [ON/OFF] button. Press the [ON/OFF] button again. The ON/OFF lamp will light up in The ON/OFF lamp will come off, green, and the operation will start. and the operation will stop. Remote controller setting Operation mode Operation mode before the power was turned off Preset temperature Preset temperature before the power was turned off Fan speed...
  • Page 8 Preset temperature for cooling Preset temperature for heating Automatic fan speed setting (For wireless remote controller) It is necessary to set for wireless remote controller only when automatic 2 Press the [F1] or [F2] button to move the cursor to the desired fan speed is not set at default setting.
  • Page 9 page Press the [F1] or [F2] button to go Main Main menu Press [F3] to go to the previous page. Vane·Louver·Vent. (Lossnay) through the vane setting options: High power Press [F4] to go to the next page. Swing "Auto", "Step 1", "Step 2", "Step 3", Timer Weekly timer "Step 4", "Step 5"...
  • Page 10 1 Select "Maintenance" from the Main Main menu Main menu (refer to page 8), and Maintenance Initial setting press the [SELECT] button. Service Main display: For PLFY-P Cursor Page follow UP/DOWN air direction setting of remote controller.) “Refrigerant address No.” and “Unit No.” are the numbers given to each air conditioner.
  • Page 11 No setting Step 1 Step 2 1 Select “Maintenance” from the Main Main menu Main menu (refer to page 8), and Maintenance Initial setting press the [SELECT] button. Service Step 3 Step 4 Step 5 Main display: Cursor Page Draft reduction* outlets Press the [SELECT] button to save the settings.
  • Page 12 2 Select the menu with the [F4] 2 When No occupancy energy save Air distribution Energy saving option button. or Room occupancy energy save M-NET address No occupancy energy save Auto vane is selected Direct/Indirect Cooling/Heating Direct/Indirect setting Select the setting with the [F4] Select: Select: Default: The vanes move the same...
  • Page 13 1 Select the setting with the [F4] Seasonal airflow Seasonal airflow button. Cooling/Heating Select: After changing the setting, press the [SELECT] button to save the setting. OFF: The function is disabled. Cooling only: When the thermostat For LOSSNAY combination turns off during cooling mode, the The following 2 patterns of operation is available.
  • Page 14 When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the emergency buttons on the grille. A DEFROST/STAND BY lamp B Operation lamp C Emergency operation cooling switch D Emergency operation heating switch E Receiver Starting operation button C for more than 2...
  • Page 15 will appear on the Main display When the is displayed on the in the Full mode when it is time to Main display in the Full mode, the Room Room system is centrally controlled and Cool Set temp. Auto Cool Set temp.
  • Page 16 1 Using both hands, pull both the bottom corners of the inlet grille to open the grille, then lift the filter until it clicks at the stop position. 2 Hold the knobs on the filter and pull the filter up, then pull it out 1 Slide the levers on the intake grille in the direction indicated by the downward.
  • Page 17 Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit.
  • Page 18 Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifications. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room.
  • Page 19 Model PKFY-P63VKM-E PKFY-P100VKM-E Power source (Voltage/Frequency) <V/Hz> ~N/220-230-240/50, 220/60 Capacity (Cooling/Heating) <kW> 7.1/8.0 11.2/12.5 Dimension (Height) <mm> Dimension (Width) <mm> 1170 Dimension (Depth) <mm> Net weight <kg> Fan Airflow volume (Low-High) <m /min> 16-20 20-25 Noise level (Low-High) <dB> 39-43 41-49 Model PLFY-P15VFM-E PLFY-P20VFM-E PLFY-P25VFM-E PLFY-P32VFM-E PLFY-P40VFM-E PLFY-P50VFM-E...
  • Page 20 ..........201 ............202 ............213 ..............206 ..............214 ................212 ...........216 ..........218...
  • Page 21 PKFY-P·VKM-E PLFY-P·VFM-E PCFY-P·VKM-E ”.
  • Page 22 Main Main menu Vane·Louver·Vent. (Lossnay) High power Room Timer Cool Set temp. Auto Weekly timer OU silent mode Main display: Cursor Page Mode Temp.
  • Page 23 2 3 4 5 6 Cool Set temp. Auto Room Set temp. Cool Mode Temp. Mode Temp.
  • Page 25 19 – 30 ºC 17 – 28 ºC 19 – 28 ºC Room Cool Set temp. Auto Mode Temp. Cool Auto Heat 28.5 Room Room Cool Set temp. Auto Cool Set temp. Auto 28.5 Mode Temp. Mode Temp.
  • Page 26 MODEL SELECT ON/OFF TEMP AUTO STOP MODE VANE AUTO START CHECK LOUVER TEST RUN RESET CLOCK Main Main menu Vane·Louver·Vent. (Lossnay) High power Timer Weekly timer OU silent mode Room Main display: Cool Set temp. Auto Cursor Page Mode Temp. Main Main menu Vane·Louver·Vent.
  • Page 27 Main Main menu Vane·Louver·Vent. (Lossnay) Swing High power Timer Weekly timer OU silent mode Main display: Cursor Page Vane Vent. Louver Auto Auto Step 1 Step 2 Step 3 Step 4 Step 5 Swing Swing OU silent mode Tue Wed Thu Fri Sat Sun Start Stop Silent...
  • Page 28 Main Main menu Maintenance Initial setting Service PLFY-P·VFM-E Main display: Cursor Page Maintenance menu Auto descending panel Manual vane angle 3D i-See sensor Main menu: Cursor Manual vane angle M-NET address Identify unit Check button Input display: Address Check Manual vane angle [F2].
  • Page 29 No setting Step 1 Step 2 Main Main menu Maintenance Initial setting Step 3 Step 4 Step 5 Service Main display: Draft Cursor Page reduction* outlets Maintenance menu Auto descending panel Manual vane angle 3D i-See sensor Main menu: Cursor ....
  • Page 30: Cooling Only

    Air distribution Energy saving option M-NET address No occupancy energy save Auto vane Direct/Indirect Cooling/Heating Room occupancy energy save Direct/Indirect setting Select: Select: Cur. Cooling only Heating Cooling/ Energy saving option Room occupancy energy save Cooling/Heating Select: Energy saving option No occupancy Auto-OFF min.
  • Page 31 Seasonal airflow Seasonal airflow Cooling/Heating Select:...
  • Page 32 COOL HEAT 24°C 24°C...
  • Page 33 Room Room Cool Set temp. Auto Cool Set temp. Auto Mode Temp. Mode Temp. Main Main menu Restriction Energy saving Night setback Filter information Error information Main display: Cursor Page Filter information Please clean the filter. Press Reset button after filter cleaning.
  • Page 35 ”.
  • Page 37 PKFY-P63VKM-E PKFY-P100VKM-E ~N/220-230-240/50, 220/60 7,1/8,0 11,2/12,5 1170 16-20 20-25 39-43 41-49 PLFY-P15VFM-E PLFY-P20VFM-E PLFY-P25VFM-E PLFY-P32VFM-E PLFY-P40VFM-E PLFY-P50VFM-E ~N/220-230-240/50, 220/60 1,7/1,9 2,2/2,5 2,8/3,2 3,6/4,0 4,5/5,0 5,6/6,3 245 (10) 570 (625) 570 (625) 14 (3) 15 (3) 6,5-7,5-8,0 6,5-7,5-8,5 6,5-8,0-9,0 7,0-8,0-9,5 7,5-9,0-11,0 9,0-11,0-13,0 26-28-30 26-29-31...
  • Page 41: Eg-Konformitätserklärung

    EG-DEKLARATION OM ÖVERENSSTÄMMELSE EG-CONFORMITEITSVERKLARING MITSUBISHI ELECTRIC AIR CONDITIONING SYSTEMS EUROPE LTD. hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben: déclare par la présente et sous sa propre responsabilité...
  • Page 42 <ENGLISH> <PORTUGUÊS> English is original. The other languages versions are translation of the original. O idioma original é o inglês. As versões em outros idiomas são traduções do idio- ma original. CAUTION CUIDADO EN378-1. in burns or frostbite. tubagem pode resultar em queimaduras ou úlceras causadas pelo frio. o seu funcionamento.
  • Page 43 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN RG79Y738H02 Printed in Thailand...

This manual is also suitable for:

Pcfy-p-vkm-ePlfy-p-vfm-e