Inside Masonry Chimney, Vertical
Installation
The wood appliance must be installed in accordance with the
applicable local laws or the CAN/CSA-B365, NFPA211 (USA)
norms. Follow the chimney manufacturer's instructions to install
the chimney.
The chimney masonry must have inside a certified metallic
sleeve cover up all the chimney height. The sleeve must be at
the same diameter of the flue collar; 6 inches (15.2 cm). The
junction between sleeve and the chimney connector must be
tight and sealed to avoid fume to go indoor.
To pass into a combustible wall between stove and the masonry
chimney. The installation method have to be safe to prevent fire.
Find the lasts information to your local authority to be sure of the
manner you have to.
To install the stove onto an abandoned masonry fireplace and
use the good condition masonry chimney the chimney must
have inside a certified metallic sleeve cover up all the chimney
height. The sleeve must be at the same diameter than the flue
collar 6 inches (15.2 cm). The junction between sleeve and the
chimney connector must be tight and sealed to avoid fume to go
indoor. Don't forget to add a sweep opening.
April 28th, 2016
Outside Vertical Installation
The wood appliance must be installed in accordance with the
applicable local laws or the CAN/CSA-B365, NFPA211 (USA)
norms. Follow the chimney manufacturer's instructions to install
the chimney.
To pass into a combustible wall between stove and the chimney.
The installation method have to be safe to prevent fire. Find the
lasts information to your local authority to be sure of the manner
you have to. An internal fire stop and an external fire stop must
be used.
17