To ensure proper tubes orientation, a groove is cut at one end
of tubes, and a corresponding emboss is cut into the hot air
side channel.
Step to install a tube.
1)
Insert the tube into the round hole into the hot air side
channel.
2)
Align and insert the groove into the other side.
3)
Push completely the grooved end and insert the cotter
pin into the last hole at the other side.
.
4)
Split the cutter pin to lock it
5)
Install the next tube
To remove tubes, do steps in reverse order

April 28th, 2016

Operating Instructions

OPERATE ONLY WHEN DOOR IS CLOSED: Keeping
the door open can over fire and do permanent damage
to the stove or a chimney fire.
It's recommended to install a CO, CO2 and smoke
detector into the same room than the stove.
NEVER SLAP THE DOOR.
NEVER BURN INFLAMMABLE LIQUID: Inflammable
liquid make too much uncontrolled heat and can make
permanent damage to the stove or a chimney fire.
ALWAYS CHEK IF AIR INLET IS NOT OBTRUCT
BEFORE LIGHTNING A FIRE.
NEVER ELEVATE FIRE WITH GRATE OR ANDRION.
ALWAYS MAKE FIRE DIRECTLY ON THE HEART.
Primary and secondary air admission
control
When the handle under the front tablet of the stove is push full
backward the air admission is from the tube only, this is what
we called "Secondary air admission". Else when the handle is
pull full forward the air admission is direct and from the top of
the door opening, this is what we called "Primary air
Admission"
Warning: Operate stove with the Primary air admission
fully open for a long period of time, can damage the stove.
IS PROHIBITED TO MODIFY AIR ADMISSION TO OBTAIN A
BRIGHT FIRE OR FOR ANY OTHER REASON.
MODIFICATION CAN AVOID GUARANTEE.

Lightning fire

After installing correctly the stove following the installation
instruction of the manufacturer, you are ready to light it.
1)
Pull the control knob forward.
2)
Put paper and lightning wood into the combustion
chamber like your preferred disposition and light it
(N.B. We recommend to use the top down lighting to
achieve better emission result)
3)
Close partially the door keeping a slight opening.
When chimney have enough heat buildup close
completely the door and lock it. Wait for a good fire
buildup.
Front -Open
Back-Close