Specifications; General Specifications - Codan X-2 Service Manual

Hf ssb
Table of Contents

Advertisement

X-2 Technical Service Manual

1.6 Specifications

This section of the manual provides specifications for the X-2 transceiver in
the following categories:
The specification figures listed are the minimum standard for the X-2
transceiver and production models will equal or exceed these figures. Where
relevant, acceptance limits are shown in brackets.
Unless otherwise specified, all measurements have been made using
13.6 V DC, with 50 Ω source and load resistances at an ambient temperature
of 25°C.
1.6.1

General Specifications

Frequency Generation
Frequency Stability
Publication No: 15-02047
General Specifications
Receiver Specifications
Transmitter Specifications
Frequency Range
Channel Capacity
Operating Modes
Programming
Cloning
Controls
2 to 18 MHz.
10 channels. Any combination of single or dual
frequency simplex.
Frequency synthesiser with 10 Hz resolution:
controlled by plug-in EEPROM.
Single sideband (J3E).
Programmable USB, LSB or front panel
switched.
USB: ±2(3)ppm
LSB: ±(2(3)ppm +10 Hz)
Long term ageing 1ppm per year.
Crystal reference oven warm up time 1 minute.
Frequencies and options are programmed via the
microphone socket and 3-wire RS232 interface
using XP programming software and an IBM
compatible PC.
Channel frequencies and options can be copied
from one transceiver to another via the
microphone socket.
Power ON/OFF and Volume.
Channel select.
Clarifier.
Mode USB/LSB.
Mute ON/OFF/Tune.
Emergency Call: RFDS 880/1320 Hz. (Australia
only)
Introduction 1-3
}
-10°C to +60°C