Setting the external connection

Setting a serial port

The <COM4 (M/S)> port can be switched between master and slave connection.
1
Select the <SYS> button → [PERIPHERAL] → [General] tab.
2
Select an item in [Master/Slave] in the [MF COM4] column.
[Master]
[Slave]

Setting a tally

Setting the tally mode
Tally mode setting will be available in V2.00.00 or higher.
Setting a tally group
1
Select the <SYS> button → [PERIPHERAL] → [Tally] tab.
2
Select an item in [Target A], [+Target B], [+Target C], or [+Target D] in the [Tally Group1‑1] column.
f Set the reference output for [Tally Group1-1] (on-air tally).
Off, ME1PGM, ME1CLN, ME2PGM, ME2CLN, DSKPGM1, DSKPGM2, DSK1CLN to DSK4CLN, AUX1 to AUX16
f Since [Tally Group1‑1] is used exclusively for on‑air tally, a preview output cannot be specified.
f Generate tally information of sources that configure any of the outputs set in [Target A], [+Target B], [+Target C], or [+Target D] in the [Tally
Group1-1] column.
3
Select an item in [Target A], [+Target B], [+Target C], or [+Target D] in the [Tally Group2‑1] to [Tally Group4‑1] columns.
f Set the reference output for [Tally Group2-1] to [Tally Group4-1].
Off, ME1PGM, ME1CLN, ME2PGM, ME2CLN, DSKPGM1, DSKPGM2, DSK1CLN to DSK4CLN, AUX1 to AUX16, ME1PVW, ME2PVW,
DSKPVW1, DSKPVW2
4
Select an item in [Color] in the [Tally Group1‑1] to [Tally Group4‑1] columns.
f Select [Red], [Green], [Yellow], or [Orange] for the color of the MultiView display.
f Since [Tally Group1] is exclusively for on‑air tally, the color is fixed to [Red].
Tally display of the MultiView display
The target of tally display of the MultiView display is [Tally Box], [Tally Label L], and [Tally Label R].
For each of those areas, [Tally Group1] to [Tally Group4] are set and displayed.
f For details on the tally display of the MultiView display, refer to "Setting the tally display" (page 114).
High tally display and bus tally display of the button
The High tally and bus tally are displayed for the next button from [Tally Group1-1] (on-air tally).
f Applicable buttons are the KEY bus crosspoint buttons, PGM/A bus crosspoint buttons, PST/B bus crosspoint buttons, corresponding buttons from
<KEY1 TRNS> to <KEY4 TRNS>, and buttons from <DSK1 TRNS> to <DSK4 TRNS>.
GPI input/output tally settings
f For each tally group, a maximum of 48 source tally outputs can be assigned to the GPI output terminal.
f The functions can be assigned in each tally group and can be enabled/disabled externally through the GPI input terminal.
f For details on GPI input/output tally settings, refer to "Setting the GPI input/output" (page 136).

Setting the GPI input/output

Set the GPI input/output port of Main Frame AV-HS60U1/AV-HS60U2, Control Panel AV-HS60C1/AV-HS60C2.
Setting the GPI input port
Functions can be assigned and externally controlled through the GPI input ports.
f The GPI input ports are the pins 1 to 18 of the <GPI IN> terminal on the Main Frame AV-HS60U1/AV-HS60U2, and the pins 1 to 8 of the <GPI I/O>
terminal on the Control Panel AV-HS60C1/AV-HS60C2. (page 145)
1
Select the <SYS> button → [PERIPHERAL] → [GPI IN] tab.
2
Select [ID] and select an item.
f Select [Mainframe], [MainPanel], [SubPanel1], or [SubPanel2] as the setting target.
([SubPanel1] and [SubPanel2] will be available in V2.00.00 or higher.)
3
Select the port where you want to assign a function from the port list in the left column.
Chapter 8 System Menu — Setting the external connection
A master connection is used.
A slave connection is used.